17.
Loop Phase Lock Adjustments
P L L 2 V C O
D I S C R I M I N A T O R
\
R 4
I
TOP VIEW
Figure 3-79. Location of
Adjustments
6. Adjust
150 MHz adjustment for a DVM indication of
0.5 Vdc. Refer to Figure 3-79 for the location of
150 MHz adjustment.
7. Adjust
MHz adjustment for a frequency counter
indication of 0.300 MHz 0.001 MHz. Refer to Figure 3-79 for the
location of
MHz adjustment.
8. On the RF Section, key in
[
START
8.599 MHz, SWEEP
TRACE A
The CRT annotation will round off to 8.59 MHz, but the RF Section is
actually set to a start frequency of 8.599 MHz.
9. Adjust
100 MHz adjustment for a DVM indication
of + 15.0 0.5 Vdc. Refer to Figure 3-79 for the location of
100 MHz adjustment.
10. Adjust
MHz adjustment for a frequency counter
indication of 0.200 0.001 MHz. Refer to Figure 3-79 for the
location of
MHz adjustment.