Fabric OS Administrator’s Guide
401
53-1002446-01
End-to-end performance monitoring
20
Access Gateway considerations for Advanced Performance Monitoring
EE monitors and frame monitors are supported on switches in Access Gateway mode. Top Talker
monitors are not supported on these switches.
EE monitors must be installed on F_Ports. Frame monitors can be installed on F_Ports or N_Ports.
See the
Access Gateway Administrator’s Guide
for additional information.
End-to-end performance monitoring
Use end-to-end (EE) monitoring when you want to monitor throughput between a pair of devices.
End-to-end performance monitoring counts the number of words in Fibre Channel frames for a
specified Source ID (SID) and Destination ID (DID) pair.
To enable EE performance monitoring, you must configure an EE monitor on a port, specifying the
SID-DID pair (in hexadecimal). The monitor counts only those frames with matching SID and DID.
Each SID or DID has the following three fields:
•
Domain ID (DD)
•
Area ID (AA)
•
AL_PA (PP)
For example, the SID 0x118a0f denotes DD 0x11, AA 0x8a, and AL_PA 0x0f.
An EE monitor includes these counts:
•
RX_COUNT - words in frames received at the port
For frames received at the port with the EE monitor installed, the RX_COUNT is updated if the
frame SID is the same as the SID in the monitor and the frame DID is the same as the DID in
the monitor.
•
TX_COUNT - words in frames transmitted from the port
For frames transmitted from the port with the EE monitor installed, TX_COUNT is updated if the
frame DID is the same as the SID in the monitor and the frame SID is the same as the DID in
the monitor.
Maximum number of EE monitors
The maximum number of end-to-end monitors supported varies depending on the switch model:
•
The Brocade DCX, DCX-4S, DCX 8510, 5100, 6505, 6510, 8000, VA-40FC, and Brocade
Encryption Switch models allow up to 1024 end-to-end monitors shared by all ports in the
same ASIC.
•
The Brocade 300, 5300, 5410, 5424, 5450, 5460, 5470, 5480, and 7800 models allow up to
768 end-to-end monitors shared by all ports in the same ASIC.
The number of interswitch links (ISLs) configured on the switch affects the amount of resources
available for end-to-end monitors.
Virtual Fabrics considerations: If Virtual Fabrics is enabled, the Brocade DCX, DCX-4S, DCX 8510
and 5300 models allow up to 256 end-to-end monitors on one logical switch. The Brocade 5100,
6510, and VA-40FC allow up to 337 end-to-end monitors on one logical switch.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Страница 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 100: ...62 Fabric OS Administrator s Guide 53 1002446 01 Configuring FLOGI time handling of duplicate PWWN 3 ...
Страница 152: ...114 Fabric OS Administrator s Guide 53 1002446 01 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Страница 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Страница 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Страница 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Страница 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Страница 374: ...336 Fabric OS Administrator s Guide 53 1002446 01 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Страница 470: ...432 Fabric OS Administrator s Guide 53 1002446 01 Disabling QoS zone based traffic prioritization 21 ...
Страница 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Страница 544: ...506 Fabric OS Administrator s Guide 53 1002446 01 Displaying the range of output ports connected to xlate domains 24 ...
Страница 554: ...516 Fabric OS Administrator s Guide 53 1002446 01 Fabric configurations for interconnectivity A ...
Страница 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Страница 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...