
164
Fabric OS Administrator’s Guide
53-1002446-01
Policy database distribution
7
Setting the fabric-wide consistency policy
1. Connect to the switch and log in using an account with admin permissions, or an account with
OM permissions for the FabricDistribution RBAC class of commands.
2. Enter the fddCfg
--
fabwideset command.
Example shows how to set a strict SCC and tolerant DCC fabric-wide consistency policy.
switch:admin>
fddcfg --fabwideset "SCC:S;DCC"
switch:admin>
fddcfg --showall
Local Switch Configuration for all Databases:-
DATABASE - Accept/Reject
---------------------------------
SCC - accept
DCC - accept
PWD - accept
FCS - accept
AUTH - accept
IPFILTER - accept
Fabric Wide Consistency Policy:- "SCC:S;DCC"
Notes on joining a switch to the fabric
When a switch is joined to a fabric with a tolerant SCC, DCC, or FCS fabric-wide consistency policy,
the joining switch must have a matching tolerant SCC, DCC, or FCS fabric-wide consistency policy. If
the tolerant SCC, DCC, or FCS fabric-wide consistency policies do not match, the switch can join the
fabric, but an error message flags the mismatch. If the tolerant SCC, DCC, and FCS fabric-wide
consistency policies match, the corresponding SCC, DCC, and FCS ACL policies are compared.
The enforcement of fabric-wide consistency policy involves comparison of only the Active policy set.
If the ACL policies match, the switch joins the fabric successfully. If the ACL policies are absent on
the switch or on the fabric, the switch joins the fabric successfully, and the ACL policies are copied
automatically from where they exist to where they are absent. The Active policies set where they
exist and overwrite the Active and Defined policies where they are absent. If the ACL policies do not
match, the switch can join the fabric, but an error message flags the mismatch.
Under both conflicting conditions, secPolicyActivate is blocked in the merged fabric. Use the
fddCfg
--
fabwideset command to resolve the fabric-wide consistency policy conflicts. Use the
distribute command to explicitly resolve conflicting ACL policies.
When a switch is joined to a fabric with any strict fabric-wide consistency policy, the joining switch
must have a matching fabric-wide consistency policy. If the fabric-wide consistency policies do not
match, the switch cannot join the fabric and the neighboring E_Ports are disabled. If the fabric-wide
consistency policies match, the corresponding SCC, DCC, and FCS ACL policies are compared.
The enforcement of fabric-wide consistency policy involves comparison of only the Active policy set.
If the ACL polices match, the switch joins the fabric successfully. If the ACL policies are absent
either on the switch or on the fabric, the switch joins the fabric successfully, and the ACL policies
are copied automatically from where they are present to where they are absent. The Active policy
set where it is present overwrites the Active and Defined policy set where it is absent. If the ACL
policies do not match, the switch cannot join the fabric and the neighboring E_Ports are disabled.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Страница 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 100: ...62 Fabric OS Administrator s Guide 53 1002446 01 Configuring FLOGI time handling of duplicate PWWN 3 ...
Страница 152: ...114 Fabric OS Administrator s Guide 53 1002446 01 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Страница 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Страница 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Страница 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Страница 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Страница 374: ...336 Fabric OS Administrator s Guide 53 1002446 01 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Страница 470: ...432 Fabric OS Administrator s Guide 53 1002446 01 Disabling QoS zone based traffic prioritization 21 ...
Страница 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Страница 544: ...506 Fabric OS Administrator s Guide 53 1002446 01 Displaying the range of output ports connected to xlate domains 24 ...
Страница 554: ...516 Fabric OS Administrator s Guide 53 1002446 01 Fabric configurations for interconnectivity A ...
Страница 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Страница 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...