Fabric OS Administrator’s Guide
305
53-1002446-01
Changing bottleneck parameters
13
Changing bottleneck parameters
When you enable bottleneck detection, you can configure switch-wide alerting and sub-second
latency criterion parameters that apply to every port on the switch. After you enable bottleneck
detection, you can change the alerting parameters on the entire switch or on individual ports. You
can change the sub-second latency criterion parameters on individual ports only. You can also
change the parameters on ports that have been excluded from bottleneck detection.
The alerting parameters indicate whether alerts are sent, and the threshold, time, and quiet time
options.
For a trunk, you can change the parameters only on the master port.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the bottleneckmon
--
config command to set the alerting and sub-second latency
criterion parameters.
Enter the bottleneckmon
--
configclear command to remove any port-specific alerting and
sub-second latency criterion parameters and revert to the switch-wide parameters.
Example
The following example disables alerts on port 1, excludes ports 2, 3, and 4 from bottleneck
monitoring, and changes the alerting parameters on ports 2 and 3. The bottleneck
--
status
command shows the settings for these ports. Note that this example changes the alerting
parameters on ports 2 and 3, even though they are excluded from bottleneck detection.
switch:admin>
bottleneckmon --config -noalert 1
switch:admin>
bottleneckmon --exclude 2-4
switch:admin>
bottleneckmon --config -alert -lthresh .99 -cthresh .9 -time
4000 -qtime 600 2-3
switch:admin>
bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold
- 0.800
Severity threshold
- 50.000
Switch-wide alerting parameters:
================================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Per-port overrides for alert parameters:
========================================
Port Alerts? LatencyThresh CongestionThresh Time(s) QTime(s)
================================================================
1 N
--
--
--
--
2 Y 0.990 0.900 4000 600
3 Y 0.990 0.900 4000 600
Excluded ports:
===============
Port
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Страница 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 100: ...62 Fabric OS Administrator s Guide 53 1002446 01 Configuring FLOGI time handling of duplicate PWWN 3 ...
Страница 152: ...114 Fabric OS Administrator s Guide 53 1002446 01 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Страница 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Страница 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Страница 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Страница 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Страница 374: ...336 Fabric OS Administrator s Guide 53 1002446 01 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Страница 470: ...432 Fabric OS Administrator s Guide 53 1002446 01 Disabling QoS zone based traffic prioritization 21 ...
Страница 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Страница 544: ...506 Fabric OS Administrator s Guide 53 1002446 01 Displaying the range of output ports connected to xlate domains 24 ...
Страница 554: ...516 Fabric OS Administrator s Guide 53 1002446 01 Fabric configurations for interconnectivity A ...
Страница 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Страница 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...