
Fabric OS Administrator’s Guide
361
53-1002446-01
SAN management with Admin Domains
17
Example of switching to a different Admin Domain context
The following example switches to the AD12 context and back. Note that the prompt changes
to display the Admin Domain.
switch:admin>
ad --select 12
switch:AD12:admin>
logout
switch:admin>
Admin Domain interactions with other Fabric OS features
The Admin Domain feature provides interaction with other Fabric OS features and across third-party
applications. You can manage Admin Domains with Web Tools as well as the CLI. If the current
Admin Domain owns the switch, you can perform Fabric Watch operations.
Admin Domain interactions do not extend to user session tunneling across switches. A user logged
in to a switch can control only the local switch ports as specified in the Admin Domain.
When the fabric is in secure mode, the following restrictions apply:
•
There is no support for ACL configuration under each Administrative Domain.
•
ACL configuration commands are allowed only in AD0 and AD255. None of the policy
configurations are validated with AD membership.
Table 63
lists some of the Fabric OS features and considerations that apply when using Admin
Domains.
TABLE 63
Admin Domain interaction with Fabric OS features
Fabric OS feature
Admin Domain interaction
ACLs
If no user-defined Admin Domains exist, you can run ACL configuration commands in only
AD0 and AD255. If any user-defined Admin Domains exist, you can run ACL configuration
commands only in AD255.
You
cannot
use ACL configuration commands or validate ACL policy configurations
against AD membership under each Admin Domain.
Advanced Performance
Monitoring (APM)
All APM-related filter setup and statistics viewing is allowed only if the local switch is part
of the current Admin Domain.
Configuration upload
and download
Refer to
“Configuration upload and download in an AD context”
on page 364 for details.
Fabric Watch
Fabric Watch configuration operations are allowed only if the local switch is part of the
current Admin Domain.
FC-FC Routing Service
You can create LSAN zones as a physical fabric administrator or as an individual AD
administrator. The LSAN zone can be part of the root zone database or the AD zone
database.
FCR collects the LSAN zones from all ADs. If both edge fabrics have matching LSAN
zones and both devices are online, FCR triggers a device import.
LSAN zone enforcement in the local fabric occurs only if the AD member list contains
both of the devices (local and imported devices) specified in the LSAN zone.
To support legacy applications, WWNs are reported based on the AD context using
NAA=5. As a result, you cannot use the NAA=5 field alone in the WWN to detect an FC
router.
FDMI
FDMI operations are allowed only in AD0 and AD255.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Страница 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 100: ...62 Fabric OS Administrator s Guide 53 1002446 01 Configuring FLOGI time handling of duplicate PWWN 3 ...
Страница 152: ...114 Fabric OS Administrator s Guide 53 1002446 01 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Страница 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Страница 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Страница 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Страница 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Страница 374: ...336 Fabric OS Administrator s Guide 53 1002446 01 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Страница 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Страница 470: ...432 Fabric OS Administrator s Guide 53 1002446 01 Disabling QoS zone based traffic prioritization 21 ...
Страница 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Страница 544: ...506 Fabric OS Administrator s Guide 53 1002446 01 Displaying the range of output ports connected to xlate domains 24 ...
Страница 554: ...516 Fabric OS Administrator s Guide 53 1002446 01 Fabric configurations for interconnectivity A ...
Страница 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Страница 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...