1-7
To do…
Use the command…
Remarks
Configure the format of the time
stamp
info-center timestamp
{
debugging
|
log
|
trap
}
{
boot
|
date
|
none
}
Optional
The time stamp format for log,
trap and debugging information
is
date
by default.
Enabling the display of system information on the console
After setting to output system information to the console, you need to enable the associated display
function to display the output information on the console.
Follow these steps in user view to enable the display of system information on the console:
To do…
Use the command…
Remarks
Enable the monitoring of
system information on the
console
terminal monitor
Optional
Enabled on the console and
disabled on the monitor
terminal by default.
Enable the display of
debugging information on the
console
terminal debugging
Required
Disabled by default
Enable the display of log
information on the console
terminal logging
Optional
Enabled by default
Enable the display of trap
information on the console
terminal trapping
Optional
Enabled by default
Outputting System Information to a Monitor Terminal
System information can also be output to a monitor terminal, which is a user terminal that has login
connections through the AUX, VTY user interface.
Outputting system information to a monitor terminal
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable information center
info-center enable
Optional
Enabled by default
Name the channel with a
specified channel number
info-center channel
channel-number name
channel-name
Optional
Refer to
Table 1-2
for default
channel names.
Configure the channel through
which system information can
be output to a monitor terminal
info-center monitor channel
{
channel
-
number |
channel
-
name
}
Optional
By default, system information
is output to the monitor terminal
through channel 1 (known as
monitor).
Содержание 4500G PWR 24-Port
Страница 200: ...1 5 ProviderB GigabitEthernet1 0 2 undo stp enable ProviderB GigabitEthernet1 0 2 bpdu tunnel dot1q stp ...
Страница 252: ...1 7 Clearing ARP entries from the ARP table may cause communication failures ...
Страница 362: ...i Table of Contents 1 Dual Stack Configuration 1 1 Dual Stack Overview 1 1 Configuring Dual Stack 1 1 ...
Страница 407: ...1 8 1 1 ms 1 ms 1 ms 1 1 6 1 2 1 ms 1 ms 1 ms 1 1 4 1 3 1 ms 1 ms 1 ms 1 1 2 2 Trace complete ...
Страница 786: ...1 16 3 In the case of PIM SM use the display current configuration command to check the BSR and RP information ...
Страница 1387: ...1 23 ...
Страница 1443: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2 ...
Страница 1720: ...ii Single Device Upgrade 3 4 IRF System Upgrade 3 5 ...