[Switch] interface gigabitethernet 1/0/1
# Set the port security mode to userLoginWithOUI.
[Switch-GigabitEthernet1/0/1] port-security port-mode userlogin-withoui
4) Verify the configuration
After completing the above configurations, you can use the following command to view the
configuration information of the RADIUS scheme named
radsun
:
<Switch> display radius scheme radsun
SchemeName : radsun
Index : 1 Type : standard
Primary Auth IP : 192.168.1.2 Port : 1812 State : active
Primary Acct IP : 192.168.1.3 Port : 1813 State : active
Second Auth IP : 192.168.1.3 Port : 1812 State : active
Second Acct IP : 192.168.1.2 Port :1813 State : active
Auth Server Encryption Key : name
Acct Server Encryption Key : money
Interval for timeout(second) : 5
Retransmission times for timeout : 5
Interval for realtime accounting(minute) : 15
Retransmission times of realtime-accounting packet : 5
Retransmission times of stop-accounting packet : 500
Quiet-interval(min) : 5
Username format : without-domain
Data flow unit : Byte
Packet unit : one
Use the following command to view the configuration information of the ISP domain named
sun
:
<Switch> display domain sun
Domain = sun
State = Active
Access-limit = 30
Accounting method = Required
Default authentication scheme : radius=radsun
Default authorization scheme : radius=radsun
Default accounting scheme : radius=radsun
Domain User Template:
Idle-cut = Disabled
Self-service = Disabled
Use the following command to view the port security configuration information:
<Switch> display port-security interface gigabitethernet 1/0/1
Equipment port-security is enabled
Trap is disabled
Disableport Timeout: 20s
OUI value:
Index is 1, OUI value is 123401
Index is 2, OUI value is 123402
Index is 3, OUI value is 123403
Index is 4, OUI value is 123404
Содержание 4500G PWR 24-Port
Страница 200: ...1 5 ProviderB GigabitEthernet1 0 2 undo stp enable ProviderB GigabitEthernet1 0 2 bpdu tunnel dot1q stp ...
Страница 252: ...1 7 Clearing ARP entries from the ARP table may cause communication failures ...
Страница 362: ...i Table of Contents 1 Dual Stack Configuration 1 1 Dual Stack Overview 1 1 Configuring Dual Stack 1 1 ...
Страница 407: ...1 8 1 1 ms 1 ms 1 ms 1 1 6 1 2 1 ms 1 ms 1 ms 1 1 4 1 3 1 ms 1 ms 1 ms 1 1 2 2 Trace complete ...
Страница 786: ...1 16 3 In the case of PIM SM use the display current configuration command to check the BSR and RP information ...
Страница 1387: ...1 23 ...
Страница 1443: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2 ...
Страница 1720: ...ii Single Device Upgrade 3 4 IRF System Upgrade 3 5 ...