1-6
z
When the current power utilization of the PSE is above or below the alarm threshold for the first
time, the system will send a Trap message.
z
When the PSE starts or stops supplying power to a PD, the system will send a Trap message, too.
Configuring a Power Alarm Threshold for the PSE
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure a power alarm
threshold for the PSE
poe utilization-threshold
utilization-threshold-value pse
pse-id
Optional
80% by default.
Upgrading PSE Processing Software Online
You can upgrade the PSE processing software online in either of the following two modes:
z
refresh mode
This mode enables you to update the PSE processing software without deleting it.
z
full mode
This mode deletes the PSE processing software and reloads it. When the PSE processing software is
damaged (in this case, you can execute none of PoE commands successfully), you can upgrade the
PSE software processing software in full mode to restore the PSE function.
Online PSE processing software upgrade may be unexpectedly interrupted (for example, an error
results in device reboot). If you fail to upgrade the PSE processing software in full mode after reboot,
you can power off the device and restart it before upgrading it again. After upgrade, restart the device
manually to make the original PoE configurations take effect.
Follow these steps to upgrade the PSE processing software online:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Upgrade the PSE processing
software online
poe update
{
full
|
refresh
}
filename pse
pse-id
Optional
Configuring a PD Disconnection Detection Mode
To detect the PD connection with PSE, PoE provides two detection modes: AC detection and DC
detection. The AC detection mode is energy saving relative to the DC detection mode.
Follow these steps to configure a PD disconnection detection mode:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure a PD
disconnection detection
mode
poe disconnect
{
ac
|
dc
}
Optional
The default PD disconnection
detection mode varies with devices.
Содержание 4500G PWR 24-Port
Страница 200: ...1 5 ProviderB GigabitEthernet1 0 2 undo stp enable ProviderB GigabitEthernet1 0 2 bpdu tunnel dot1q stp ...
Страница 252: ...1 7 Clearing ARP entries from the ARP table may cause communication failures ...
Страница 362: ...i Table of Contents 1 Dual Stack Configuration 1 1 Dual Stack Overview 1 1 Configuring Dual Stack 1 1 ...
Страница 407: ...1 8 1 1 ms 1 ms 1 ms 1 1 6 1 2 1 ms 1 ms 1 ms 1 1 4 1 3 1 ms 1 ms 1 ms 1 1 2 2 Trace complete ...
Страница 786: ...1 16 3 In the case of PIM SM use the display current configuration command to check the BSR and RP information ...
Страница 1387: ...1 23 ...
Страница 1443: ...i Table of Contents 1 URPF Configuration 1 1 URPF Overview 1 1 What is URPF 1 1 How URPF Works 1 1 Configuring URPF 1 2 ...
Страница 1720: ...ii Single Device Upgrade 3 4 IRF System Upgrade 3 5 ...