background image

38(1 1/2")

61(2 3/8"

)

267(10 1/2")

125(4 15/16") 

36(1 7/16") 

43(1 11/16") 

7.5(5/16"

)

MANUFACTURER'S STATEMENT

DETECTION AREA

OUTER DIMENSIONS AND PART NAMES

ENGLISH

ORIGINAL

5919151 MAR 2013

TM-0072-7

(1) Connector

(2) Mounting holes

(3) Operation indicator

(4) Width adjustment screws

(5) Depth angle adjustment screw

(6) Function switch

(7) Microwave sensitivity potentiometer

(8) Dipswitches 

(9) Detection window

(10) Area adjustment tool

Model 

Cover color

Mounting height

Detection area

Detection method

Depth angle

        adjustment

Power supply *2

Power consumption

Operation indicator

Test input

Activation output 

: OAM-DUAL T / TV / TF / TT       

: Black   

: 2.0 (6'6") to 3.5m (11'6") 

: See 

DETECTION AREA

: Active infrared reflection *1

  Microwave doppler effect
: AIR area -6  to +6°

  Microwave area +25  to +45°   

: 12 to 24VAC ±10% (50 / 60 Hz)

  12 to 30VDC ±10%             

: < 2.5W (< 4VA at AC)

: See 

Operation indicator table

: Opto coupler

  Voltage 5 to 30VDC

  Current 6mA Max. (30VDC)


: See 

INSTALLATION 2

Safety / test output

Output hold time

Response time

Operating temperature

Operating humidity

IP rate

Category

Weight

Accessories

Performance level

: Opto coupler (NPN)

  Voltage 5 to 50VDC

  Current 100mA Max.

  Dark current 600nA Max.

                     (resistance load)

: <0.5 sec.

: <0.3 sec.

:  -20 to +55°C (-4 to 131°F)

: <80%     

: IP54

: See 

Table 1

: See 

Table 1

: 320g (11.2oz )  

: 1 Operation manual

  2 Mounting screws

  1 Mounting template

  1 Area adjustment tool

  1 Cable 3m (9'10")

   (8 × 0.22mm² AWG24 ) *3

The specifications herein are subject to change without prior notice due to improvements.

NOTE

It is required to check the operation manual if this symbol is shown on the product.

MANUFACTURER'S STATEMENT

WARNING

Do not wash, disassemble, rebuild or repair the sensor, otherwise 

it may cause electric shock or breakdown of the equipment. 

Danger of electric shock

WARNING

CAUTION

NOTE

Disregard of the warning symbol can cause improper operation which may cause death 

or serious injury.

Special attention is required to the section of this symbol.

Disregard of the caution symbol can cause improper operation which may cause injury of a

person or damage the object.

NOTE

Read this operation manual carefully before use to ensure proper operation of this product.

Failure to read this operation manual may cause improper operation and may result in serious injury or death of

 a person.The meanings of the symbols are as follows.

1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door. 

    Do not use for any other applications. 

2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.

3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to

    the product.

4. Only use the product as specified in the operation manual provided.

5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which 

    the product is installed.

6. Before leaving the installation site make sure that the product is operating properly and instruct the building

    owner/operator on proper operation of the door and the product.

7.The product settings can only be changed by an installer or service engineer. When changed, the 

   changed settings and the date shall be registered in the maintenance logbook accompanying the door.

The actual detection area may become smaller depending on the ambient light, the color / material of

the object or the floor as well as the entry speed of the object.

The sensor may not be activated when the entering speed of the object or a person is slower than 

50mm / sec. or faster than 1500mm / sec.

NOTE

[mm (inch)]

Operation indicator table

A1:2009

EN61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3

COMPLIANCE

CAUTION 

Risk of getting caught

Make sure to affix the mounting template as described in the above chart,

otherwise it can be dangerous since there may be no detection area around 

the threshold. Install the sensor as low as possible on the header.

WARNING

Danger of electric shock

Do not use the sensor without the cover. 

When using the cable knockout, install the sensor indoors or use the rain cover 

(separately available) otherwise electric shock or breakdown of

 the sensor may occur. 

Before starting the procedure, make sure that the power is turned OFF.

When passing the cable through the hole, do not tear the shield

otherwise it may cause electric shock or breakdown of the sensor.

4

Wire the cable to the door controller as shown below.

1.Plug the connector.

2.Supply power to the sensor.  Adjust the detection area and set the dipswitches. 

   (See 

ADJUSTMENTS 4. Dipswitch settings

)

Place the housing cover.

If wiring is to be exposed, break the knockout.

H : Height from the floor to the bottom of the header

Y : Distance between the bottom of the header and the sensor

X : Distance between the door and the mounting surface

WARNING

Danger of electric shock

NOTE

Make sure to connect the cable correctly to the door controller before turning the power ON.

When turning the power ON or after adjusting the settings, do not enter the detection area for more 

than 10 seconds in order to enable the presence detection.

Do not touch the dipswitches before turning the power ON, otherwise an error occurs.

After changing the dipswitches and/or potentiometer, make sure to push the function switch for 2 seconds.

INSTALLATION

The following conditions are not suitable for sensor installation.

 -Fog or exhaust emission around the door

 -Wet floor

 -Vibrating header or mounting surface

 -Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity

 -Highly reflecting floor or highly reflecting objects around the door

 
 

NOTE

X

H

Y

Sensor

Door

Header

Floor

SPECIFICATIONS

(10)

(1)

(4)

(5)

(8)

(6)

(9)

(3)

(2)

Machinery Directive 2006/42/EC

Notified Body: TÜV SÜD Product Service GmbH, Daimlerstraße 40 60314 Frankfurt Germany

Noise level

: <70dBA

1. Affix the mounting template at the desired mounting position.

2. Drill two mounting holes of ø3.4mm (ø1/8”).

3. To pass the cable through the header, drill a wiring hole of ø8mm (ø5/16”).

4. Remove the mounting template.

5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.

Refer to the chart in below.

EN ISO13849-1:2008

EN ISO13849-2:2008

EN16005:2012
EMC Directive 2004/108/EC

1

2

3

4

AIR 

Microwave

Mounting height : 2.2m(7'2")

Vertical adjustment : +35°

Sensitivity : H

Area width : wide

Speed of detection object 

                  : 50mm / sec.

Mounting height : 2.2m(7'2")

Angle adjustment : +6°

Sensitivity : M

: Emitting spots

: Detection area

: Emitting spots 

  (can be eliminated)

: Detection area

AutSchR (OAM-DUAL TV/TF/TT Only)

1sec.

1sec.

Set-up

Stand-by  (installation mode)

Stand-by  (operation mode)

Setting error

Signal saturation

Sensor failure

2nd row detection

Lookback (1st row) detection*4

3rd row detection

Microwave detection

Status

Yellow blinking

Green

Red & green blinking

Slow green blinking

Fast green blinking

Yellow

Orange

Red 

 Operation indicator color

Red blinking

Blue

(7)

LOOKBACK AREA

When dipswitch 15 is set to ON, the lookback area, that provides extra safety over the threshold, is activated.

In case the lookback function is not required, set dipswitch 15 to OFF.

Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.

Lookback

(1st row)

2nd row

3rd row

Lookback

(1st row)

2nd row

3rd row

  12 to 24VAC±10% / 12 to 30VDC±10%

  

Opto coupler(NPN) / Voltage: 5 to 50VDC

Form A relay 

50V 0.3A Max.

Opto coupler / Voltage: 5 to 30VDC

1.White

2.Brown
3.Green
4.Yellow
5.Pink (+)

6.Blue (-)
7.Red (+)

8.Black (-)

Power

supply

Safety /

test output

Activation

output

Test input

2

1

3

4

Voltage output 3.2V@10mA

Min. 4.5V(no load)

(+)

(-)

Frequency output

100Hz±10%

1

2

3

4

Form A relay 

50V 0.3A Max.

Opto coupler / 

Voltage: 5 to 30VDC

5

OAM-DUAL T

OAM-DUAL TV

OAM-DUAL TF

OAM-DUAL TT

*2  : The sensor has to be connected to a door system which has a SELV circuit.

*4  : See 

LOOKBACK AREA

*1  : Active infrared reflection has a presence detection function.

*3  : Overcurrent protection with less than 2A.

Table 1

Cat.

AIR

part

Microwave

part

PL

Cat.

PL

OAM-DUAL T OAM-DUAL TV OAM-DUAL TF OAM-DUAL TT 

d (EN ISO13849-1 : 2008)

d (EN ISO13849-1 : 2008)

2 (EN ISO13849-1 : 2008)

2 (EN ISO13849-1 : 2008)

Test conditions required by EN16005

Floor :Grey paper

Detection object : EN 16005 CA reference body

Sensitivity : middle

Speed of detection object : 50mm / sec.

To comply with EN16005, make sure that the detection area is within the values of the chart below.

AIR detection area

 

The chart shows the values at depth angle +6°

AIR emitting area

A
X
G

I*

2.20 (7'2")

2.00 (6'6")

0.25 (10")
1.12 (3'8")
2.65 (8'8")

3.00 (9'10")

0.34 (1'1")
1.53 (5')
3.60 (11'10")

0.23 (9")
1.02 (3'4")
2.41 (7'11")

The values mentioned in "detection area" refer to the test conditions as described in the EN16005  

(the emitting area is specified in "emitting area").  

*: When installed at higher than 3.0m(9'10"), EN16005 requirements are fulfilled only within the area width "I" 

   of 3.6m(11'10"). 

[m(feet,inch)]

A

C

B

G

H

0

1000

(3′3")

1000(3′3")

2000(6′6")

1000

(3′3")

2000

(6′6")

2000

(6′6")

Lookback(1st row)

2nd row

3rd row

D E

F

A
B
C
D
E
F

G
H

2.20 (7'2")

0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")

2.70 (8'10")

0.10 (4")
0.31 (1')

3.00 (9'10")

0.11 (4")
0.34 (1'1")

0.48(1'7")
0.80 (2'8")

0.53 (1'9")
0.89 (2'11")

1.63 (5'4")

1.81 (5'11")

2.50 (8'2") 

0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51(4'11")

2.00 (6'6")

0.07(3")

0.06 (2")

0.074(3")

0.08 (3")

0.07 (3")

0.05(2")

0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")

2.05 (6'9")

2.51 (8'3")

2.79 (9'2")

2.32 (7'7")

1.86 (6'1")

I

2.78 (9'1")

3.40 (11'2") 3.79 (12'5")

3.50 (11'6")

0.12 (5")
0.39 (1'4")
0.61 (2')
1.03(3'5")
2.11 (5'11")

0.09 (4")

3.25 (10'8")
4.42 (14'6")

3.15 (10'4")

2.52(8'3")

[mm(feet,inch)]

Maximum distance (Y)

X

2.00 (6' 6")

2.30 (7' 6") 2.50 (8' 2") 2.80 (9' 2")

0

No limit

0.05 (2")

0.13 (5")

0.13 (5")

0.14 (6")

0.10 (4")

0.11 (4")

0.12 (5")

0.12 (5")

0.12 (5")

0.15 (6")

0.10 (4”)

0.10 (4”)

0.11 (4")

0.11 (4")

0.20 (8")

-

0.09 (4”)

0.10 (4”)

0.10 (4”)

0.25 (10")

0.09 (4”)

0.30 (12")

-

-

H

0.13 (5")

-

-

-

-

0.09 (4")

[m (feet,inch)]

3.00 (9'10") 3.50 (11'6")

0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")

-

0
0
0
0
0
0

NOTE

Make sure not to mount the sensor lower than the bottom of header.

X

Mounting

surface

1.White

2.Brown
3.Green
4.Yellow
5.Pink (+)

6.Blue (-)
7.Red (+)

8.Black (-)
9.Gray/Pink (+)

10.Red/Blue (-)

Power

supply

Safety /

test output

Activation

output

Test input

(Safety)

2

1

3

4

Test input

(Activation)5

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: