IN-19
Monosplit “Wall” Personal Line Constant Speed - Section 5: Installation
Indoor Unit
2(N)
1(L)
1(L)
3
4
Yellow / Green
Yello
w / Green
Bro
wn
Blue
Red (Example)
Orange (Example
)
Power supply (on Indoor Unit):
1-Phase, 220~240V, 50 Hz.
Calibration of circuit breaker and power supply switch:
- Model 261 G → 10A
- Models 351 G and 531 G → 16A.
Min. section of power supply cables:
- Models 261 G and 351 G → 1.5mm
2
- Model 531 G → 2.5mm
2
.
Example of wiring: “Constant Speed” Models HKED-HCND 261, 351, 531G
Outdoor Unit
Min. section of wiring between Units:
- Model 261 G → 1.5mm
2
- Models 351 G and 531 G → 2.5mm
2
.
2(N) 3
4
Grounding
Grounding