Monosplit “Wall” Personal Line Constant Speed - Section 1: General Information
How to orient airflow in vertical direction:
CAUTION
a) Optimized airflow or fixed position
Control electronics adjusts in optimal way
(
“natural flow”
) the movement of horizontal flap
so as to simulate a light air current inside the
room.
In this case, remote control’s display will show
the indicator .
If you would like to change the angle of
horizontal flap as regards default setting for
each operation mode, press “SWING” button
twice, till fixed default position is reached.
In this case, remote control’s display will show
the indicator .
Carr y out these adjustments while the
system is operating.
b) Continuous swinging (“SWING”)
Carry out this adjustment while the system is
operating.
Press (once or twice) “SWING” button till
reaching continuous swinging in ver tical
direction (up/down) of horizontal airflow flap.
In this case, remote control’s display will show
the flashing indicator .
Press “SWING” button again to go back to
default fixed position of horizontal flap for each
operation mode.
Carr y out these adjustments while the
system is operating.
Carry out this adjustment according to your comfort needs, and avoid to direct airflow to people,
plants and animals.
Angle of airflow in vertical direction can be set by remote control.
If system is OFF, “SWING” button does not start any function.
Do not operate system for a long time with horizontal flap completely addressed downwards in
Cooling mode and in Dr y mode, to avoid that condensate for ms on the flap itself, and that
condensate may drip inside the room.
When air conditioner is started, the horizontal flap will start moving after a certain time, that is after
inner electronics has undertaken its control.
If system is stopped by remote control, and air conditioner was operating in Cooling mode or in Dry
mode, horizontal flap will automatically move to closing position only after about 30 seconds. This
allows to remove the remaining humidity from Indoor Unit’s heat exchanger and prevent the forming
of mould.
If horizontal flap does not work properly, stop the system, disconnect it and wait for a few minutes.
Then connect it again, start it and check if horizontal flap is operating properly now.
The angle of horizontal flap must never be too much small, to avoid a too much choking of air outlet
and consequent lowering in performances.
Room relative humidity should always be lower than 80%. If air conditioner is operating in Cooling
mode at higher levels of humidity, the surface of indoor heat exchanger may get convered with frost
(till causing the intervention of special protective function). If this occurs, please adjust horizontal flap
1.8 HOW TO ADJUST AIR DIRECTION
n
Adjustment of airflow in vertical direction
Содержание HCND 261 G
Страница 100: ...Notes 1 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 101: ...Notes 2 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 102: ...Notes 3 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 103: ...Notes 4 Monosplit Wall Personal Line Constant Speed Notes Notes ...