Monosplit “Wall” Personal Line Constant Speed - Section 1: General Information
1.10 AUTO-RESTART FUNCTON AFTER A BLACKOUT
A blackout during system’s operation, immediately causes the system’s stop.
When power is restored, Operation LED (“Running”) on Indoor Unit will start blinking.
Normally, if the system was ON when the blackout occurred, it is able to automatically restart after
3 minutes have elapsed since power is restored.
Therefore, it is not necessary to press ON/OFF button on remote control, except for accidental deletion
of operation data memory (EEPROM). In this case only, the system cannot automatically restart, and it
will be necessary to use the IR remote control or the Emergency Button.
At the end of the blackout, the system’s operating setting will be the same as when the system stopped.
Automatic start/stop of air conditioner, programmed by “Timer On/Off” functions, or the starting up
of “SLEEP” function will be cancelled so a new “TIMER” setting or “SLEEP” setting must be carried out.
CAUTION
If the system is used to air-condition an environment where people live occasionally, it is
recommended to stop it before leaving the building and to disconnect the system by main
switch, and/or disconnect the plug from the power socket, such as additional safety measure.
Move main switch to OFF
Disconnect the plug from the power socket
Содержание HCND 261 G
Страница 100: ...Notes 1 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 101: ...Notes 2 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 102: ...Notes 3 Monosplit Wall Personal Line Constant Speed Notes Notes ...
Страница 103: ...Notes 4 Monosplit Wall Personal Line Constant Speed Notes Notes ...