![Hioki MR8740-50 Скачать руководство пользователя страница 160](http://html1.mh-extra.com/html/hioki/mr8740-50/mr8740-50_instruction-manual_2137326160.webp)
154
Numerical Calculation Types and Descriptions
Calculation
type
Description
When a Y data point corresponds to an X data point
s
0
Start point
End point
X-axis (Y = 0)
Area
S
=
s
0
s
0
End point
Start point
X-axis (Y = 0)
Area
S
= −
s
0
s
0
Start point
End point
X-axis (Y = 0)
Area
S
= −
s
0
s
0
End point
Start point
X-axis (Y = 0)
Area
S
=
s
0
s
0
s
1
When a waveform includes negative
amplitude
Start point
End point
When multiple Y data points
correspond to an XY data point
X-axis (Y = 0)
Area
S
=
s
0
−
s
1
s
0
s
0
s
1
s
2
X-axis (Y = 0)
Area
S
=
s
0
X-axis (Y = 0)
Area
S
=
s
0
+ 2 ×
s
1
+
s
2
Time to level
Searches a calculation range from the beginning
for the time when a signal crossed the specified
level and calculates a period of time from a
trigger point to a point searched for.
Settings:
Level
,
Slope
,
Filter
0 V
Level
Level at time
Calculates a level when the specified time has
elapsed from a trigger point.
You can also specify a time based on previously
calculated results.
Settings:
Method
(
Time
,
Calc. No.
),
Time/
calculation number
(
No. 1
to
No.107
)
0 V
Level
T (Time)
Pulse width
Calculates a pulse width based on a time lag
between the time when a waveform crossed
the specified level in the positive (or negative)
direction and the time when it next crossed the
specified level in the opposite direction.
Settings:
Level
,
Slope
,
Filter
,
Stat.
Level
Duty ratio
Calculates a duty ratio based on a time lag
between the time when a waveform crossed the
specified level in the positive direction and the
time when it next crossed the specified level in
the opposite direction, and a time lag between
the time when the waveform crossed the
specified level in the negative direction and the
time when it next crossed the specified level in
the opposite direction.
=
× 100 [%]
T
u-d
T
u-d
T
d-u
+
Duty ratio
T
u-d
: Time from rising edge to falling edge (unit: s)
T
d-u
: Time from falling edge to rising edge (unit: s)
Settings:
Level
,
Filter
,
Stat.
Level
T
u-d
T
d-u
Содержание MR8740-50
Страница 2: ......
Страница 6: ...Contents iv...
Страница 40: ...34 Enlarging a Part of the Waveform Zoom Function...
Страница 86: ...80 Configuring Generator Module Specific Settings...
Страница 128: ...122 Automatically Specifying the Trigger Level Auto trigger Level...
Страница 164: ...158 Numerical Calculation Types and Descriptions...
Страница 182: ...176 Displaying Waveforms...
Страница 186: ...180...
Страница 214: ...208 Operating the Instrument With a Browser Installed in a Computer...
Страница 224: ...218 External Sampling EXT SMPL...
Страница 232: ...226 Information for Reference Purposes...
Страница 236: ...230 Index...
Страница 237: ......