Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
550
IV Appendix
No. Content Remark
6744
When 4th axis is allocated with an absolute encoder without a reference
point, a reference point is set after the machine is debugged normally
6745
When 5th axis is allocated with an absolute encoder without a reference
point, a reference point is set after the machine is debugged normally
6746
When 6th axis is allocated with an absolute encoder without a reference
point, a reference point is set after the machine is debugged normally
6751
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis X
equipped absolute encoder. Check up parameters and renew to set
machine zero points
6752
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis Z
equipped absolute encoder. Check up parameters and renew to set
machine zero points.
6753
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis Y
equipped absolute encoder. Check up parameters and renew to set
machine zero points.
6754
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis
4TH equipped absolute encoder. Check up parameters and renew to set
machine zero points.
6755
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis
5TH equipped absolute encoder. Check up parameters and renew to set
machine zero points.
6756
Gear ratio of CNC or servo ,the direction of axis moving and the machine
zero points are not as different as data established successfully while axis
6TH equipped absolute encoder. Check up parameters and renew to set
machine zero points.
6761
The batteries of absolute encoder are too low as axis X equipped absolute
encoder. Renew batteries and set machine zero point again.
6762
The batteries of absolute encoder are too low as axis Z equipped absolute
encoder. Renew batteries and set machine zero point again.
6763
The batteries of absolute encoder are too low as axis Y equipped absolute
encoder. Renew batteries and set machine zero point again.
6764
The batteries of absolute encoder are too low as axis 4th equipped absolute
encoder. Renew batteries and set machine zero point again.
6765
The batteries of absolute encoder are too low as axis 5th equipped absolute
encoder. Renew batteries and set machine zero point again.
6766
The batteries of absolute encoder are too low as axis 6th equipped absolute
encoder. Renew batteries and set machine zero point again.
6771
Machine zero point Can't be returned because no zero point position is
established as axis X of equipping absolute encoder
6772
Machine zero point Can't be returned because no zero point position is
established as axis Z of equipping absolute encoder
Содержание 980TDi
Страница 17: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 1 Programming I Programming...
Страница 225: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 209 Operation II Operation...
Страница 379: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 363 Connection III Connection...
Страница 539: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 523 IV Appendix IV Appendix...