Appendix VI Alarm List
549
IV Appendix
No. Content Remark
6613 GDT data check error
6620 IDN16, 24 allocation fails
6621 IDN32,35 allocation fails
6622 IDN5030,5031,5033 allocation fails
6630 I/O unit allocation fails
6702
Setup machine zero point again please. Because the parameter file of zero
point failed to save as using absolute encoder motor
6703
Setup machine zero point again please. Because the parameter file of zero
point failed to read as using absolute encoder motor.
6711
The error of actual position and memory position oversteps the range
permitted as axis X equipped absolute encoder. Return machine zero point
manually and set zero point again.
6712
The error of actual position and memory position oversteps the range
permitted as axis Z equipped absolute encoder. Return machine zero point
manually and set zero point again
6713
The error of actual position and memory position oversteps the range
permitted as axis Y equipped absolute encoder. Return machine zero point
manually and set zero point again
6714
The error of actual position and memory position oversteps the range
permitted as axis 4TH equipped absolute encoder. Return machine zero
point manually and set zero point again.
6715
The error of actual position and memory position oversteps the range
permitted as axis 5TH equipped absolute encoder. Return machine zero
point manually and set zero point again.
6716
The error of actual position and memory position oversteps the range
permitted as axis 6TH equipped absolute encoder. Return machine zero
point manually and set zero point again.
6721
Initialization of machine coordinates makes a mistake while starting as axis
X equipped absolute encoder. Reset machine zero point again.
6722
Initialization of machine coordinates makes a mistake while starting as axis
Z equipped absolute encoder. Reset machine zero point again.
6723
Initialization of machine coordinates makes a mistake while starting as axis
Y equipped absolute encoder. Reset machine zero point again.
6724
Initialization of machine coordinates makes a mistake while starting as axis
4TH equipped absolute encoder. Reset machine zero point again
6725
Initialization of machine coordinates makes a mistake while starting as axis
5TH equipped absolute encoder. Reset machine zero point again.
6726
Initialization of machine coordinates makes a mistake while starting as axis
6TH equipped absolute encoder. Reset machine zero point again.
6741
When X axis is allocated with an absolute encoder without a reference point,
a reference point is set after the machine is debugged normally
6742
When Z axis is allocated with an absolute encoder without a reference point,
a reference point is set after the machine is debugged normally
6743
When Y axis is allocated with an absolute encoder without a reference point,
a reference point is set after the machine is debugged normally
Содержание 980TDi
Страница 17: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 1 Programming I Programming...
Страница 225: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 209 Operation II Operation...
Страница 379: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 363 Connection III Connection...
Страница 539: ...Official GSK Agents in South Africa Tel 27 11 626 2720 design efamatic com 523 IV Appendix IV Appendix...