76
308607
Horizon System Components
Fluid Solenoid Valves
Part No. 218588, Fluid Solenoid Valve
0 to 3 gpm (0--11.4 liter/min.), with Ready Light; See
manual 307696 for more information
Part No. 215487, Fluid Solenoid Valve
0 to 3 gpm (0--11.4 liter/min.), without Ready Light; See
manual 307696 for more information
Part No. 512927, Fluid Solenoid Valve
0 to 6 gpm (0--22.7 liter/min.), without Ready Light
Part No. 238996, Ready Light Kit
Technical Data
Category
Data
Type
2 way, normally closed
Electrical Rating
28 V DC, 0.46 amp
NOTE: provides minimum
current draw when operated at
24 V DC
Coil Insulation
Class H
Leads
18 AWG x 18.0 in. (457 mm)
long
Maximum Working
Pressure
3000 psi (21 MPa, 207 bar)
Inlet/Outlet
1/2 npt
Minimum Actuation Volts
Required
20
Wiring Gauge Required
(by cable length)
18 AWG up to 50 ft. (15.3 m)
IN
or
2
Fluid Solenoid
OUT
or
1
NOTE:
Part No. 512927 is marked 2
at the inlet and 1 at the outlet.
Air Solenoid Valves
Part No. 215407, Air Solenoid Valve; Low Flow
For low-air-flow requirement pump models, such as the
Eagle
t
and Fire-Ball
r
Part No. 512926, Air Solenoid Valve; High Flow
For higher-flow pump models, such as the President
r
Technical Data
Category
Data
Type
3 way solenoid operated air
valve, normally closed
Electrical Rating
24 V DC, 0.25 amps
Coil Insulation
General purpose, Class A
Encapsulated, Continuous
Duty
Leads
18 AWG x 12.0 in. (305 mm)
long
Inlet/Outlet
Part No. 215407
Part No. 512926
Adapted to 3/8 npt
3/8 npt
Wiring Gauge Required
(by cable length)
18 AWG up to 50 ft. (15.3 m)
1
2
IN
OUT
3
Part No. 215407 shown
NOTE:
Part No. 512926 uses
the same number indicators for
the inlet, outlet, and exhaust.
EXHAUST
Air Solenoid
Fluid and Air Solenoids
Solenoids are electrically operated by the control
module they are connected to. The fluid solenoids start
and stop the fluid dispense cycles. The air solenoids
open and close the air supply to the pump.
Solenoid Specifications:
D
Up to 6 solenoids can be connected to each control
module.
D
A fluid solenoid must be placed at each dispense
point for each fluid being dispensed.
D
The use of air solenoids to turn off pressure to the
pumps when a fluid is not being dispensed is
strongly recommended. Standard thermal/pressure
relief design practices should be followed also.