308607
9
Installation Checklist
System Startup
n
Installation Steps
Reference
13. Turn on the printer or computer.
14. Turn on the AC power to each control module. All the keypads should briefly
display a revision screen and then the HOME screen. The printer should print
“WELCOME TO HORIZON...” If the HOME screen is not displayed and/or
there is no print-out, see
Troubleshooting
, page 68.
Page 19
15. Using the Administrative Keypad, which is connected to the Master Control
Module, access the Setup screens. The Password is 1111 for a new system
installation.
Page 19
16.
If your system has one control module only,
disable the CAN network.
Page 21
17. Select CLEAR SETUP to initialize the system. Be sure to enter a new pass-
word for setup access before exiting Setup.
Page 23
18. Using the administrative keypad, connected to the Master Control Module,
complete the System Setup. Use the six forms that were filled out in the
Pre-installation Procedure
(refer to step 8, page 7) to enter the System
Map information into the Setup screens.
Pre-installation Forms
and Appendix, pages
86--95, or page 22,
New Setup Options
19. After entering all the setup data, reboot the system (turn the main power off
then on) to initialize the software.
Test the System
n
Installation Steps
Reference
20. Request a dispense job for each fluid to each location. If any problems occur,
see
Diagnostics
, page 26, and troubleshooting information on page 61.
Pages 48 -- 52
21. Select SETUP
!
PRINT SETUP
!
ALL MEMORY to print a record of all the
data entered during Setup. Send a copy of this record and all other required
documents as instructed in Pre-installation Form 6,
Warranty Registration &
Checkout Form
.
Pages 24 and 96
System Installation Complete
Содержание Horizon Fluid Management Systems