85
System Configuration
Example 2 Configuration
D
3 fluids
D
All 3 fluids dispensed in each of 3 bays
D
Simultaneous dispensing of all fluids to all bays
D
One keypad in the office, plus a keypad in each bay
D
Printer in the office for output
The Example 2 Parts List is the minimum needed to
support the Example 2 Configuration. The requirement
for a keypad in each bay forces the inclusion of addi-
tional control modules. The total of 12 solenoids and 9
meters could be handled by 2 control modules (6 ports
on each for solenoids and six ports on each for me-
ters), but each control module has only one port for
attaching a keypad.
Example 2 Parts List
Qty.
Component
1
Master Control Module
3
Slave Control Module
4
Keypads (could be 1 Administrator Keypad
for setup and 3 Basic Keypads for the bays)
3
Air Solenoids
9
Fluid Solenoids
9
Pulse Meters
1
Printer
1
Printer Cable, 25 or 50 ft. (7.6 or 15.3 m)
4
Keypad Cable, 25 or 50 ft. (7.6 or 15.3 m)
1
Solenoid Cable, bulk spool
1
Meter Cable, bulk spool
1
Network Cable, bulk spool
06513A
Example 2
#1 (Master)
#2
#3
#4
#7
#8
#9
#7
#8
#9
#7
#8
#9
#1
#2
#3
#1
#2
#3
#1
#2
#3
#1
#2
#3