SCIP Configuration
Configuring Typical SCIP Networks
076R200-000
SpectraComm IP T1 Router Card
3-9
Issue 13
Installation and Operation Manual
3. Configure the T1 values for your network.
configure t1 clock-source
[line]
configure t1 fdl
[ANSI-T1.403]
configure t1 framing
[ESF]
configure t1 lbo ds1
[0.0dB]
configure t1 linecode
[B8ZS]
configure t1 timeslots
[1-24 64]
Note
When configuring the Line Buildout for DSX1, SCIP uses five ranges of lengths: 0 - 133 ft, 133-266 ft,
266-399 ft, 399 - 533 ft, 533-655 ft. Be aware that if you select a value at the beginning of a range, such as
133 ft, SCIP will use the lower range that includes that value.
Note
Type
show t1
to check your T1 value entries. Modify, if needed.
4. Configure the Ethernet IP address and mask by typing:
configure interfaces ip-address ethernet0
[###.###.###.###] [###.###.###.###]
For example:
configure interfaces ip-address ethernet0 172.16.5.6 255.255.0.0
5. Enter a description of the Ethernet interface by typing:
configure interfaces description ethernet0
[your_description]
For example:
configure interfaces description ethernet0 orlando_lan
6. Enable the Ethernet interface by typing:
configure interfaces enable ethernet0
7. Configure the serial0 interface (at the T1 port) for Frame Relay DTE by typing:
configure interface link-encap serial0 frame-relay-dte
8. Enable the serial0 interfaces by typing:
configure interfaces enable serial0
9. Configure the serial0 sub-interface to support Frame Relay DLCIs by typing:
configure interfaces add-sub serial0.
[##]
For example:
configure interfaces add-sub serial0.17
10. Enter a description for the serial0 sub-interface by typing:
configure interfaces description serial0.
[##]
[your_description]
For example:
configure interfaces description serial0.17 noc_miami
11. Enable the s0 sub-interface by typing:
configure interfaces enable serial0.
[##]
For example:
configure interfaces enable serial0.17