7 PRINTER STATUS AND SYSTEM MESSAGES
Two kinds of status transmission are available for the default print modes.
1.
Default status message via flags called A8 status messages
2.
Extended status message with protocol called C32 status messages
Simple messages are based upon the flag principle. Each flag of a status byte corresponds to a message. To make a
distinction between the 5 status bytes and other data, status bytes are in always situated above 80hex. Moreover the
upper flags are used as identifiers to make it possible to identify the individual status bytes.
Extended messages are always transferred in an ASCII format with a secured data format. A message contains an
identifier and a checksum to recognize defective transmissions.
In the
parameter module 12
“message" and
module 30
“message_A8", simple as well as extended messages can be
configured to decide whether they shall be sent automatically or on demand, also which kind of messages are sent or if
they are sent at all.
7.1 CONFIGURATION OF EMULATION SPECIFIC MESSAGES
Parameter:
12,14:
emulation specific messages
1: emulation specific status messages and C32 simultaneously
0: emulation specific messages only
7.2 SETTINGS FOR ADDITIONAL MESSAGES
(no status messages)
Parameter:
12,3
Output of syntax error messages in extended format
1: enable /
0: disable
12,4
Output of internal error messages in extended format
1: enable /
0: disable
7.3 SETTINGS OF EMULATION SPECIFIC STATUS MESSAGES
Parameter:
12,7
emulation specific automatic status messages enable/disable
1:on
/ 0:off
12,8
periodically emulation specific status message in [ms]
0: off
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 33 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.