SOFTWARE MANUAL C32
21.3 SWITCHED PCL COMMANDS
<ESC>“*““r““B“ End Raster Graphics Command
<ESC>“*““r““C“ End Raster Graphics Command, reset compression mode, leftmargin = 0
The
parameters 38,10, 38,11, and 38,12
determine which actions are executed when these commands are given.
Parameter:
38,10:
End of graphics <ESC>“*““r““C“ and <ESC>“*““r““B“ execute a formfeed
38,11:
End of graphics <ESC>“*““r““C“ and <ESC>“*““r“„“B“execute a EoT
38,12:
End of graphics <ESC>“*““r““C“ and <ESC>“*““r““B“ execute the batch file no. 38,12. 0:= no batch file executed..
These commands are ignored when there is no entry in this batch file or when the parameter = 0).
21.4 ELIMINATE EMPTY ROWS
Parameter 38,9 "Default maximum empty rows" determines how many successive empty rows are needed, until they are
eliminated. This makes a length limitation of blank spaces possible.