8.2 PRINTER OPERATION STATUS
The printer status indicates the general state of the system. Several states can be active at the same time. The state
which is actually the most important is displayed in each C32 message at the end of the use data range.
According to configuration different status indications via LED.
# <Status> <Level> <further messages>
Info levels are just information in the system, no user action needed.
INFO
0: OK everything is OK no messages
INFO
1: fast loading
INFO
2: trickle charging
INFO
3: completely charged
INFO
5. preheating head
INFO
6: head preheating temperature reached
Warning levels represent a system error, but nevertheless allow further printing. According to level user action is urgent.
WARNING
1: There is no problem yet, but there will be one in the future. e.g. near paper end.
WARNING
3: A problem is expected very soon.
WARNING
5: Firmware detected an error which nevertheless allows printing with limitations (emergency operation).
Service should be carried out as soon as possible. If for example the EEprom is not found the printer
works uses firmware parameters.
Error levels represent serious system errors, making further printing impossible. According to the error level, it will be
easy or difficult to correct that error.
ERROR
1: Firmware has detected an error that might be corrected via remote maintenance.
(e.g. service or on/offline)
ERROR
3: Firmware has detected a simple error that prevents the printer from working. Service can restore the
printing: e.g. paper end, paper jam....
ERROR
5: Firmware has detected a fatal error. System repair is needed and the error can not be corrected by
simple service action.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 39 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.