SOFTWARE MANUAL C32
19 N78 EMULATION
19.1 CONFIGURATION OF PRINTER IN N78 EMULATION
N78 printer are set with the batch file Tinit. When starting the system commands for the printer configuration are sent to
the system. In the C32 system this is not designed. All system parameters of the C32 system are available.
19.2 EMULATED COMMANDS
The following commands of the N78 system are emulated:
For command description see manual SoMAN-N78-E-0485 resp. SoMAN-N78-D-0484.
In the following only differences to the original N78 system are explained.
Command description value range
<FF>
Form FEED to the set length or to mark (TOF)
<ESC> "A"
Erases the data in the printer buffer
<ESC> "b" p1 ....p8
Prints barcode (EAN8, EAN13, CODE 39, 2 of 5 interleaved)
<ESC> "C" n
0: full cut / 1: half cut / 2: cutter init
<ESC> "D" n
Print text mode / data mode
n:={0,1}
<ESC> "e" n,m
Sleep mode (power down only)
<ESC> "F" lh ll
Paper feed (Feed) by l
h
x 256 + l
l
lines.
<ESC> "g" n g1....gn
Pixel graphics PCL5 , print graphics line with n byte length
<ESC> "H" n
Change character height 0: single height up to 7: eight fold height
n:={0,1, ...,7}
<ESC> "I" n
Print black on white / white in black
n:= {0,1}
<ESC> "k"
Return actual status
<ESC> "L" n
Print with / without underlining
n:= {0,1}
<ESC> "l"p
h
p
l
Set side lenght
p
h
:={1, .,4}; p
l
:={1, .. ,4}
<ESC> "m" n
Set graphics mode (Select coding)
n:={$00 , .. , $05}
<ESC> "m" n o
Offset to the right for graphics
<ESC> "N" p
h
p
l
Go to the absolute dot position p = 256 x p
h
+ p
l
.
<ESC> "o"
Set start of page
<ESC> "P" n
Select character set number. n
n:={1, .. ,n}
<ESC>“Q“ n
Old N34 quality command (see note at the end of the chapter)
<ESC> "R" p
h
p
l
Relatively move (back or forth) to the dot position
p = 256 x p
h
+ p
l
.
<ESC> "S" n
Increase character spacing
<ESC> "T" x
Print batch file no. x
x:= { 0 ...255)
<ESC> "V" X
Send synchronized character "X" to host
<ESC> “v“ n
Read statistics
n:= {1,2,3,4}
n := 0 Reading cuts
n := 1 Reading the total operational performance of the printer mechanism in 1/10 meters.
Example: 000001A9 = 425, 42,5m paper length
n := 2 Reading operation time in abt. 1/10 hours
Example: 000001A9 = 425, 42,5 operation hours
n := 3 Reading paper length since last change of paper roll in 1/10 meters
Paper end sets the counter to zero.
n := 4 Reading the last 10 error messages. Not realized. Output is always "XXXXXXXXXX".
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 140 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.