SOFTWARE MANUAL C32
Module 17
Renderer
17,1
e_w
number of job buffer elements
17,2
e_w
number of object list elements
17,3
e_w
size of renderer RAM [byte]
17,4
u_a
number of leftmost dot within printing area
0: no left margin
17,5
u_a
number of leftmost dot beyond printing area / at least printer width
0: no right margin
17,6
u_a
number of topmost dot line from top of form within printing area
0: no top margin
17,7
u_a
number of topmost dot line from top of form beyond printing area
0: uncapped
17,23
u_w
basic scaling factor X
HINT: Restrictions on barcodes and logos
17,24
u_w
basic scaling divisor X
HINT: Restrictions on barcodes and logos
17,25
u_w
basic scaling factor Y
HINT: Restrictions on barcodes and logos
17,26
u_w
basic scaling divisor Y
HINT: Restrictions on barcodes and logos
17,27
u_w
system font initial scaling factor width
17,28
u_w
system font initial scaling divisor width
17,29
u_w
system font initial scaling factor height
17,30
u_w
system font initial scaling divisor height
17,31
u_w
AddOn font initial scaling factor width
17,32
u_w
AddOn font initial scaling divisor width
17,33
u_w
AddOn font initial scaling factor height
17,34
u_w
AddOn font initial scaling divisor height
17,35
u_w
RAM logo buffer size
Module 18
18,1
e_w
size of image drum [dot lines]
18,2
e_w
starting speed of printer motor [mm/s]
18,3
u_a
maximum speed of printer motor [mm/s]
(max.=500)
18,4
u_a
maximum backwards speed [mm/s]
(max.=500)
18,5
e_w
printer motor backlash [dot lines]
18,6
u_a
printing density
default = 25
18,7
u_a
bytes per soft strobe
18,8
u_a
heated bytes per soft strobe
18,9
e_a
latency after stall condition [ms]
default = 40
18,10
u_w
stall timeout [ms]
18,11
r/o
motor follow-up time [ms]
18,12
u_a
ticket length control
1: enabled / 0: disabled
18,13
u_a
blackmark minimum length [dot lines]
default = 3
dot lines
number of black lines until detection of blackmark
18,14
u_a
blackmark sensor index
0: PaperEnd
1: AUX1 / 2: AUX2 / 3: AUX3 / 4: AUX4
5: AUX5 / 6: AUX6 / 7: AUX7
18,16
u_a
distance from start of most recent blackmark to form feed position [dot lines]
TOF = 0 dot lines
18,17
u_a
number of segments per ticket
0: variable number
blackmarks per ticket 0-31
default = 0
0: each blackmark is used and is overwriteable
1: each blackmark is used, too long printouts will be cut
2: every other blackmark is used, too long printouts will be cut
3: every third blackmark is used, too long printouts will be cut
18,21
u_a
Autoload
1: enabled / 0: disabled
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 23 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.