SOFTWARE MANUAL C32
16.7 SYSTEM PARAMETER COMMANDS
System parameters are used for system configuration. When switching on the printer or after a reset the values filed in
FLASH (default values ex works) or EEPROM (modifications designed to user specifications) are stored in copy in the RAM
and are activated. According to system parameters the value may be changed by the user during operation. Please pay
attention to the access rights for the respective system parameter.
16.7.1 READING HOST INTERFACE INFORMATION
[Command identifier]
SyspRead
[1. Parameter]
System parameter identifier
accepted wild cards:
0,0:
all system parameters of all modules
x,0:
all system parameters of the module x
[2. Parameter]
series of identifiers for required information
FIRM: firmware parameter value
FACT: factory parameter value
UEEP: EEPROM parameter value
URAM: RAM parameter value
HINT:
access rights and help texts
[Description]
If several identifiers are noted, these are separated with empty spaces. Output are single
messages in preset order. If wildcards are used for the system parameter identification an end
identification is sent after the message string of the last system parameter.
Abbreviation
User modifications
r/o
not tolerated
e_w
in expert mode only, activation only after RESET
e_a
in expert mode only, activation possible without RESET
u_w
in user mode, activation only after RESET
u_a
in user mode, activation possible without RESET
GeBE Elektronik und