SOFTWARE MANUAL C32
18,22
u_a
maximum autoload speed [mm/s]
default: minimum speed
of printer mechanism [mm/s]
18,23
u_a
autoload feed length [mm]
default = 100,
max. 255 mm
18,24
u_a
autoload stopping status
default = 0
0: ToF
– Attention! Parameter 18,39 > 18,23
1: AUX1 / 2: AUX2 / 3: AUX23/ 4: AUX4 / 5: AUX5 / 6: AUX6 / 7: AUX7
8: insertion sensor / 9: picking sensor / 10: blackmark / 11: none
18,25
u_a
reverse autoload feed
1: enabled / 0: disabled
18,26
u_a
subsequent backwards feed to autoload [dot lines], negative =: feed forwards
18,27
u_a
extension of printable area after PaperEnd detection [dot lines]
0-500 (
default = 122
)
18,28
e_w
printer motor step mode
0: full step / dot line
1: half step / dot line
18,29
e_a
fixed strobes on time [µs]
0: variable strobes on time
18,30
e_a
minimum strobes off time [µs]
18,31
e_w
acceleration of printer motor [mm/s²]
18,32
e_a
fixed S.L.T. [µs]
0: variable S.L.T.
18,33
u_a
T: autoflush on PaperEnd
18,34
u_a
autoflush timeout [s]
0: no timeout
18,35
u_a
T: EoT terminates autoflush
18,36
e_w
micro step resolution: 1...8
18,37
e_w
motor current: 0...31
(hardware dependent)
18,38
e_w
motor current in general 0: = low / 1: = high
(hardware dependent)
18,39
u_a
ticket segment length: e.g. distance of blackmarks [decimillimeter]
18,40
u_a
ticket length allowance for blackmark detection [mm]
18,41
u_a
minimum paper snippet length [mm]
for consecutive form feeds
18,42
u_a
autoflush on head up
default: F:
none
18,43
u_a
feed at PaperEnd also
default: F:
no feed
18,44
e_a
anti jam sensor
0: NONE, 1: AUX1, 2: AUX2, 3: AUX3, 4: AUX4, 5: AUX5, 6: AUX6, 7: AUX7
18,45
u_w
motor current settings for STSPIN220: from minimum to maximum value in %
18,46
u_w
motor stall detection, minimum speed in mm/s
(default 150, 0 = off)
18,47
u_a
history scheme
18,48
u_a
print history strobe length percentage
18,49
u_a
batch no. 17 printer motor idle timeout [s], 0 : no timeout
(1–64000 seconds = 18 hours)
18,50
u_a
T. HeadDn terminates autoflush
18,51
e_a
threading sensor, 0: NONE , 1: AUX1 , 2: AUX2 , 3: AUX3 , 4: AUX4 , 5: AUX5 , 6: AUX6 , 7: AUX7
18,52
u_a
feed lenght ToF to threading sensor [decimillimeter]
18,53
u_a
T. autoflush on feed jam
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 24 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.