SOFTWARE MANUAL C32
23.10.1 DEBUG COMMAND
Debug command for detecting and reading important timing parameters on module Stats:
Only available with DEBUG fimware versions!
Reading with <RS> 'xt' <n>,
Resetting with <RS> 'dt' <n>
<n> = 0: all Tracing data
<n> = 1: Motor1-S.L.T. [us]
<n> = 2: Printer-call-delay [us]
<n> = 3: Printer-runtime PRINTISRSTATE_IDLE [us]
<n> = 4: Printer-runtime PRINTISRSTATE_RESUME [us]
<n> = 5: Printer-runtime PRINTISRSTATE_PRELINE [us]
<n> = 6: Printer-runtime PRINTISRSTATE_STARTLINE [us]
<n> = 7: Printer-runtime PRINTISRSTATE_PREHEAT [us]
<n> = 8: Printer-runtime PRINTISRSTATE_DOSTROBES [us]
<n> = 9: Printer-runtime PRINTISRSTATE_CLOSELINE [us]
<n> = 10: Printer-runtime PRINTISRSTATE_AWAIT_STATUS [us]
<n> = 11: Printer-runtime PRINTISRSTATE_FIRSTLINE [us]
<n> = 12: Printer-runtime PRINTISRSTATE_NOLINE [us]
<n> = 13: Printer-runtime PRINTISRSTATE_SUSPEND [us]
Depending on above mentioned timing, 3 values will be issued: moving average, miniumum and maximum average. This
data area is empty for not yet recorded data. (Actually no average will be calculated for several values - therefore the
moving average is equal to the actual value.)
Automatic reset of all data with each POR (no storage in EEPROM).