SOFTWARE MANUAL C32
12.4.8 SETTING OPTICAL DENSITY
[Name]
Density on/off
[Format]
ASCII
<ESC> “Y“
n
Hex
1Bh
59h
n
Decimal
27d
89d
n
[Description]
This parameter can be set between 0 and 50. High values imply high density. Typical default value is: 25.
i.
12.4.9 BOLD ON/OFF
[Name]
Bold on/off
[Format]
ASCII
<ESC> “J“
n
Hex
1Bh
4Ah
n
Decimal
27d
74d
n
[Description]
This command is effective from the letter after which it is given.
The character's graphics data are shifted to the right and “OR” linked with the original.
n := 0 bold off, n := 1 bold on
12.4.10 UNDERLINE ON/OFF
[Name]
Underline on/off
[Format]
ASCII
<ESC> “L“
n
Hex
1Bh
4Ch
n
Decimal
27h
76d
n
[Description]
This command is effective from the letter, after which it is given until it is cancelled.
12.4.11 REVERSE
[Name]
Reverse on/off
[Format]
ASCII
<ESC> “I“
n
Hex
1Bh
49h
n
Decimal
27d
73d
n
[Description]
Printing black/grey on white.
This command is effective from the letter, after which it is given until it is cancelled.
Action: 0:= normal printing, 1:= white on black
12.4.12 TEXT ORIENTATION
[Name]
Text orientation
[Format]
ASCII
<ESC> “D“
n
Hex
1Bh
44h
n
Decimal
27d
68d
n
[Description]
Reverse printing in text mode (n = "0") or in data mode (n = "1"). In data mode the text is turned in an
angle of 180° in order to make it readable when the paper strip is hanging down. Thus the chronology
of the print lines appears upside down. This command has no effect on graphics. It can be given at any
position within a line, as long as the line is not yet terminated and it affects the whole line. This
command is effective until it is cancelled.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 96 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.