SOFTWARE MANUAL C32
8.18.4 EXIT MONITORING
For printers with exit sensor.
The exit sensor is used to monitor ticket printout. As long as a ticket occupies the exit sensor or the output slot is blocked,
the further processing is stopped. The output can be indicated by the "Option LED" or the output bezel flashing.
8.18.4.1 PARAMETER SETTINGS
Parameter 24,9
picking sensor
0 :=
NONE /
1: =
AUX1 /
2:=
AUX2 /
3 :
= AUX3 /
4 :=
AUX4 /
5 :=
AUX5 /
6 :=
AUX6 /
7 :=
AUX7
Activate monitoring of ticket output via specified sensor. No monitoring at value 0.
Parameter 12,13
automatic flashing during EoT state
The level of the threading sensor is preset for a reflex sensor. If the sensor “sees” paper, a jam is assumed.
This setting can be changed in module 19.
8.18.4.2 STATUS MESSAGES
Setting the extended status flags no. 21
Tipp:
The bezel should flash as soon as printing begins. This is achieved by giving the command <RS>$<0d><1d> <0d> at the
beginning of printing. The flashing is automatically stopped by the EoT sequence.