SOFTWARE MANUAL C32
14.4.3 SCALE GRAPHICS DATA
[Command identifier]
ScalingG
(short form ScG)
[1. parameter]
Scaling of width: rational number
[2. parameter]
Scaling of height (optional): rational number
If not, width and height are scaled with the same factor.
[Examples]
Graphics of double width and half height
[GeBE#ScG2:1/2]
Graphics of one and a half width and height
[GeBE#ScG 1.5]
[Description]
The command has to be issued previous to the data to be scaled. If not, the frame is closed.
Scaling parameters follow the coordinate system of the frame. The resulting scaling needs to
be displayed as a fraction with numerator and denominator of [1, 255]. Scaling factors thus
can be provided in steps of a fraction of 1 over 255 from
1
/
255
up to maximum 255. If necessary
the system rounds adequately or limits the value so that limit values can be met.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 120 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.