SOFTWARE MANUAL C32
19.3 NEW COMMANDS FOR THE N78 EMULATION
19.3.1 PRINT STORED LOGO
[Name]
Print logo with number n
[Format]
ASCII
<ESC>
“#“
n
Hex
1Bh
23h
n
Decimal
27d
35d
n
[Description] The stored AddOn logo with the ordinal number n is printed in the actual cursor position. The left offset
can be set with the command <ESC>m<4d><offset in mms>. The ordinal number of the logo is determined
with the A8 logo patch table.
19.3.2 POWER OFF
The power off can either be performed automatically after a set time or by command.
The power down acts like a reset.
The wake-up or restart can be initiated by the following actions:
•
press the power-on button briefly
•
connect the USB cable
•
connect the charging cable
•
switch on RS232-RTS
Hint: Shutdown is prevented if any of the above wake-up criteria persists.
With the GeBE-FLASH, the red LED flashes in this case.
19.3.2.1 SETTING POWER OFF VIA SYSTEM PARAMETERS
[Name]
Power Down
[Format]
Parameter 3,1
in seconds
0 seconds:
no power down
resp. after
10..28800 seconds:
power down
[Description]
If the parameter is set and the hardware conditions for the power down are met,
the controller switches off automatically after the set time.
19.3.2.2 SETTING POWER OFF VIA COMMAND
[Name]
Set Power Off mode
[Format]
ASCII
<ESC>
“e“
n
m
Hex
1Bh
65h
n
m
Decimal
27d
101d
n
m
[Description] The command allows to set the waiting time or to stop the power off (if waiting time = 0)
Parameter n
Waiting time until Power Off.
n = 0
infinity; i.e. Power Down is switched off
n = 10...28800 Power off after a certain time
Parameter m
Time evaluation
m = 0
Power Off time in seconds
m = 16
Power Off time in minutes
m = 32
Power Off time in hours
Hint: there is an automatic limitation of the value to 10 seconds minimum and 8 hours maximum.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 142 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.