8.18.3 ANTI JAM ERROR
For printers with anti-jam unit.
The exit or anti jam sensor is used to monitor the ticket printout or a paper jam in the printer.
If the exit sensor is activated during printing, the printout stops immediately. Deactivating the print will continue a
printout after a certain time.
8.18.3.1 PARAMETER SETTINGS
Parameter 18,44
Anti Jam sensor index
0 :=
NONE /
1: =
AUX1 /
2:=
AUX2 /
3 :
= AUX3 /
4 :=
AUX4 /
5 :=
AUX5 /
6 :=
AUX6 /
7 :=
AUX7
Activate monitoring of ticket output via specified sensor. No monitoring at value 0.
The level of the threading sensor is preset for a reflex sensor. If the sensor “sees” paper, a jam is assumed.
This setting can be changed in module 19.
8.18.3.2 STATUS MESSAGES
Setting the error status GeBE_C32 status flag current no. 23 in case of paper jam.