SOFTWARE MANUAL C32
19.5 N78 STATUS
Print filed logo
[Name]
Print logo with number n
[Format]
ASCII
<ESC>
“k“
n
Hex
1Bh
6Bh
n
Decimal
27d
107d
n
[Description]
Returnall actual (error) status messages. The controller sequentially returns all actual states. If no
message is available a "X" is returned. This command is not performed immediately. As it is treated
like a printable character, it is not performed until all previously sent characters were attended to
in the parser. In this special case it is possible to enable automatic repeat of the error messages.
n = "0"
Repeat function disabled
n = (1,...254d) The actual printer status is sent to the host in intervals of about n seconds.
n = (255d)
Single request with no influence on the set repeat time.
19.6 N78 ERROR MESSAGES
If a status is changed or an error occurs, one or several ASCII characters are sent automatically via the serial interface,
that can be evaluated by the host. If the error is eliminated the corresponding small character is sent, followed by a "X", if
no further error occurs.
Message
Message
Print is
LED
LED
Meaning
error
error OK
interrupted
Dual
green
of error
R
-
-
green 30:1
green on
reset
X
-
-
green 30:1
green on
error eliminated
H
h
X
red 5Hz 1:1
5Hz 1:1
head lifted
P
p
X
red 5Hz 1:1
5Hz 1:1
paper end
Z
z
-
green 5Hz 3:1
5Hz 3:1
near paper end
C
c
X
red 5Hz 1:1
5Hz 1:1
cutter blocked
K
k
X
red 5Hz 1:1
5Hz 1:1
head temperature low
T
t
X
red 5Hz 1:1
5Hz 1:1
head temperature high
U
u
X
red 5Hz 1:1
5Hz 1:1
VP too low
M
m
X
red 5Hz 1:1
5Hz 1:1
VP too high
?
-
-
green 30:1
green on
parity error
Hint for old N34 systems:
Instead of the command <ESC>“[„ n m for the setting of power consumption and print dynamics/quality, in the N34 systems there were the
commands <ESC>"Q" n for print quality and <ESC>“[„ n for power consumption.
If the command <ESC>“Q“ n is given in the N78 emulation it is accepted and then cancelled.
Then the command <ESC> “[„ expects a parameter n for the power consumption. Now the printing quality can only be set with the
system
parameter 18,7
.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 144 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.