SOFTWARE MANUAL C32
8.16 MOTION SENSOR
As soon as the printer is switched on the motion sensor (64bit) permanently checks the paper movement in both
directions in printer resolution units. The "read motion position" command enters the last covered distance in forward
direction into the motion position counter and displays it. Now these contents can be compared to the included printer
position counter.
ATTENTION: The maximum measuring length of the sensor is 380 mm. Latest after this length a reading operation must have been
occured.
[Name]
Read Motion Position
[Format]
ASCII
<RS>
“x“
“p“
“0“
Hex
1Eh
78h
70h
30h
Decimal
30d
120d
112d
48d
[Name]
Read Motion Position – Reset Motion Position Counter
[Format]
ASCII
<RS>
“x“
“p“
“1“
Hex
1Eh
78h
70h
30h
Decimal
30d
120d
112d
48d
[Description]
The sensor contents are added to the sensor position counter and displayed as 64bit value.
If the last command parameter is = 0, both values are read. If it is „1“, the motion position counter is
additionally equalized with the printer position counter.
8.16.1 RESPONSE OF A MOTION SENSOR
[aR:0x00000027#[0x0011FFCEms0x00310000
0x0000000A
:
0x0000000A
#i_+]#0x96808FE5:aR]
Printer position counter value:
motion position counter value
The module 49 (31h) reports that 10 dot lines have been covered since the last poweron. The configuration of the motion
sensor is carried out via module 49 (31h).
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 73 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.