SOFTWARE MANUAL C32
4 SYSTEM CONFIGURATION
One set of parameters is used to configure the printer system in all kind of emulations. For more transparency these
parameters are grouped in modules. Some of the parameters are permanently linked to the hardware and can only be
changed ex factory. Within one module, the parameter index addresses the parameter. Command parameters have to be
entered in ASCII format.
Input 18,2 addresses parameter no. 2 in parameter module no. 18.
All permanent parameter settings will be stored in the printer's FLASH, EEPROM or RAM. Different storage levels will be
used to save the settings.
4.1 STORAGE LEVELS
–
FIRMWARE SETTINGS:
The printer's basic setting is stored in the printer's FLASH memory within the firmware. It is not changeable and
always the same for each firmware. On demand, these FACTORY SETS can be adapted ex factory.
–
FACTORY SETTINGS
(not implemented yet, actually realized in firmware settings)
:
The printer's basic settings are stored in the FACTORY SETS, changeable ex factory only. By command, a reset to the
basic FACTORY SETS is possible. In delivery status, factory- and user sets are identical.
–
USER SETTINGS:
Ex works the factory settings are additionally saved as a copy in the internal EEPROM. With each poweron or
reset, the user settings will be read for operation. With command „Set printer parameter“ the user settings may
be changed and saved.
–
RAM SETTINGS (temporary):
RAM settings will be deleted after reset or power-off and reset to USER SETTINGS at next power-on.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 16 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.