23.10 REQUEST ANALOG VALUES
(old debug command)
[Command]
<RS> “x“ “a“ 0d
The command issues the analogue values for all 8 available analogue channels:
Output as 16 bit value per AD channel.
The resolution of the converter is only 12 bits. That means, the upper 4 bits are always 0.
Channel 8 :
AUX 7
(additional VP measuring / battery temperature)
Channel 9:
AUX 1
( Blackmark)
Channel 10:
Vp
Channel 11 :
Head Temp
Channel 12:
Paper End
Channel 13:
AUX 5
( Motor temperature / pressure sensor)
Channel 14:
Near Paper End
Channel 15:
AUX 2
(2. Blackmark / Head Alignment )
[Example]
<RS>xa<0d>
Reply to Module 12 message, with the message ID: GMID = 0x000C and the message code = 0x0001
[aR:0x00000062#[0x00016E83ms
0x000C0001
: 0x000006AC,
0x0809, 0x0FFF, 0x0D91, 0x07B7, 0x0146,
0x07EE, 0x0FFF, 0x04AE
#w_+]#0x0A0080BD:aR]
Reply are all 8 ADC channels from channel 8 -15 (depending on hardware)