Site preparation
2-9
3. Allow sufficient space so the nut is free of the welded seam and there is room for tools
(min. 50 mm).
4. Use the dimensions in the following figure to prepare the mast flange for mounting of
the ADU.
CAUTION!
Avoid sharp edges where the flange is in
direct contact with the radome. Round all edges as much as
possible to avoid damaging the surface of the radome.
Figure 2-8: ADU mast flange, distance to the welded seam
Figure 2-9: ADU, bottom view
50
W
elded seam
W
elded seam
Gusset plate
Allow sufficient space so the
nut is free of the welded seam
and there is room for tools
(min. 50 mm).
Clearance hole
for M12 bolts
New antenna
Current antenna
R326
248
ø350
247.5
247.5
N-Connector
164.5
247.5
247.5
452
270.5
72.5
M12
ø350
Содержание FV-110GX
Страница 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Страница 16: ...xiv This page is intentionally left blank ...
Страница 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Страница 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Страница 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Страница 135: ...Alternative ground for steel hulls A 5 Figure A 3 Grounding at a dedicated RF ground alternative ...
Страница 164: ...Supported commands C 10 This page is intentionally left blank ...
Страница 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Страница 166: ...OEM declaration D 2 D 1 OEM declaration ...
Страница 173: ...OD 1 30 Jul 2018 H MAKI ...
Страница 174: ...OD 2 30 Jul 2018 H MAKI ...
Страница 175: ...OD 3 2 Oct 2018 H MAKI ...
Страница 176: ...OD 4 2 Oct 2018 H MAKI ...
Страница 178: ......
Страница 186: ......