List of ACU events
B-8
B.3
List of ACU events
Error
code
(ID)
ACU
PCB
Severity
Description
Explanation
08060-0 ADM WARNING Antenna modem
ACU/Antenna communication error detected
(framing and parity). If the situation is persistent,
check if cable specifications comply (length and
attenuation).
08063-0 ADM ERROR
Antenna connection The ACU has lost connection with the antenna.
08064-0 ADM ERROR
ADM PLL lock
The intermediate frequency PLL is not in lock.
Check the 10 MHz reference signal.
08065-0 ADM WARNING GNSS data
Missing GNSS data (fix).
08066-0 ADM WARNING Heading data
Missing heading information. Check cable and
heading provider device.
08067-0 ADM ERROR
PCB temperature
ADM temperature too high. Make sure there is
compliance with the environmental
specifications.
08068-0 ADM ERROR
PSM power
The PSM fails to provide the requested supply
voltage.
08069-0 ADM WARNING Blocking Zone
The antenna has entered a blocking zone.
0806A-0 ADM WARNING VMU connection
The ACU has lost connection with the sat
modem.
0806C-0 ADM ERROR
VMU frequency
setup
There is a mismatch in the frequency setup.
Probably the sat modem is not configured
correctly to match the requirements of the ACU
and antenna. A common mismatch is the absence
of Rx or Tx LO parameter in the VSAT modem.
0806D-0 ADM ERROR
Antenna power
The antenna supply voltage is outside the
allowed limits. This may happen if the PSM fails
to provide the requested supply voltage.
0806E-0 ADM ERROR
VMU reference
signal
There is no VMU Rx or Tx reference signal.
Whether this is Rx or Tx reference depends on
the user's selection on the modem profile page in
the web interface. Make sure VMU Rx/Tx cable
is connected and that the VMU is configured to
output the RX/TX reference signal.
Table B-2: ACU event messages
Содержание FV-110GX
Страница 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Страница 16: ...xiv This page is intentionally left blank ...
Страница 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Страница 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Страница 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Страница 135: ...Alternative ground for steel hulls A 5 Figure A 3 Grounding at a dedicated RF ground alternative ...
Страница 164: ...Supported commands C 10 This page is intentionally left blank ...
Страница 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Страница 166: ...OEM declaration D 2 D 1 OEM declaration ...
Страница 173: ...OD 1 30 Jul 2018 H MAKI ...
Страница 174: ...OD 2 30 Jul 2018 H MAKI ...
Страница 175: ...OD 3 2 Oct 2018 H MAKI ...
Страница 176: ...OD 4 2 Oct 2018 H MAKI ...
Страница 178: ......
Страница 186: ......