List of ADU events
B-3
0A018-0 Antenna ERROR
ISM ABS
device
Cannot initialise the ISM Info:
0x00000000: Device not found (possible
cabling problem)
0x000cbbaa: Device internal error (replace
device) aa=status, bb=state, c=calibration data
error.
0A019-0 Antenna ERROR
PMM ABS
device
Cannot initialise the PMM. Info: See 0A015-0.
0A01A-0 Antenna ERROR
BCM ABS
device
Cannot initialise the BCM. Info: See 0A015-0.
0A01E-0 Antenna ERROR
Sensor sanity
Too many invalid values measured by the ISM
during initialisation. Check for vibrations or
malfunctioning ISM.
0A021-0 Antenna ERROR
Azi axis
calibration
Azimuth axis zero reference not found. Check
belt and zero reference module. Info:
0x00000001: Timeout (operation did not
complete in time)
0x00000010: Encoder or mechanical problem
0x00000020: Zero reference not found
0x00000040: End stop not found.
0A022-0 Antenna ERROR
Xel axis
calibration
Cross-elevation axis zero reference or end
stops not found at expected locations. Check
belt, zero reference module, and end stops.
Info: See 0A021-0.
0A023-0 Antenna ERROR
Ele axis
calibration
Elevation axis zero reference or end stops not
found at expected locations. Check belt, zero
reference module, and end stops. Info: See
0A021-0.
0A025-0 Antenna ERROR
Antenna
calibration
One or more errors occurred during antenna
start-up Info:
0x00000001: Timeout (calibration did not
complete in time)
0x00000010: Azimuth axis
0x00000020: Cross-elevation axis
0x00000040: Elevation axis
0x00000080: Polarisation axis
0A028-0 Antenna ERROR
Demodulator
load
The second receiver demodulator cannot be
initialised and loaded correctly.
0A029-0 Antenna ERROR
XIM PLL lock
The PLL on the VIM/TIM does not lock.
Error
code (ID)
Unit
Severity
Description
Explanation
Table B-1: ADU event messages (Continued)
Содержание FV-110GX
Страница 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Страница 16: ...xiv This page is intentionally left blank ...
Страница 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Страница 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Страница 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Страница 135: ...Alternative ground for steel hulls A 5 Figure A 3 Grounding at a dedicated RF ground alternative ...
Страница 164: ...Supported commands C 10 This page is intentionally left blank ...
Страница 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Страница 166: ...OEM declaration D 2 D 1 OEM declaration ...
Страница 173: ...OD 1 30 Jul 2018 H MAKI ...
Страница 174: ...OD 2 30 Jul 2018 H MAKI ...
Страница 175: ...OD 3 2 Oct 2018 H MAKI ...
Страница 176: ...OD 4 2 Oct 2018 H MAKI ...
Страница 178: ......
Страница 186: ......