List of ACU events
B-9
0806F-0 ADM WARNING ROSS
synchronization
The ACU has become out of sync with the ROSS
device, most likely because the ACU has been
replaced, or the ROSS satellite profile is new. A
manual (forced) handoff sequence must be
initiated from the ROSS, refer to the ROSS
manual.
08075-0 ADM WARNING VMU TX
frequency invalid
The satellite modem did not provide a Tx
frequency, or it is invalid. A default Tx
frequency is assumed, but this may degrade Tx
performance. To remove this warning re-
configure the modem to provide the correct Tx
frequency.
08078-0 ADM WARNING VMU TX
frequency invalid
The satellite modem unit provided a TX
frequency of zero. This may degrade tx
performance. To remove this warning re-
configure the modem to provide the correct tx
frequency.
08079-0 ADM WARNING ACU Fan
Internal Fan is malfunctioning.
0807A-0 ADM WARNING Automatic azimuth
calibration pending
Automatic azimuth calibration mode is enabled.
The system tries to perform an azimuth
calibration using the target satellite whenever
satellite data is received from the modem. After
successful calibration the feature is automatically
disabled and the system returns to normal
operation. WARNING: If a system has not
completed azimuth calibration after the
installation, the blocking zones may appear to be
at wrong angles.
0807B-0 ADM WARNING BUC calibration
outdated
BUC calibration is outdated. Rerun it from the
Core Module by using the One Touch
Commissioning in the web interface.
0807C-0 ADM ERROR
System
configuration
Invalid ACU / antenna combination.
0807F-0 ADM WARNING Local
administration
enabled
Local administration mode is currently enabled.
This allows login without providing the admin
password. Will be disabled after 1 hour or next
reboot.
08100-0 ADM ERROR
PSM low voltage
(22 V)
The ADM measures a different antenna voltage
than expected. If the problem is not solved by a
restart, and the PSM is not reporting any errors,
the ADM is probably defective.
Error
code
(ID)
ACU
PCB
Severity
Description
Explanation
Table B-2: ACU event messages (Continued)
Содержание FV-110GX
Страница 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Страница 16: ...xiv This page is intentionally left blank ...
Страница 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Страница 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Страница 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Страница 135: ...Alternative ground for steel hulls A 5 Figure A 3 Grounding at a dedicated RF ground alternative ...
Страница 164: ...Supported commands C 10 This page is intentionally left blank ...
Страница 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Страница 166: ...OEM declaration D 2 D 1 OEM declaration ...
Страница 173: ...OD 1 30 Jul 2018 H MAKI ...
Страница 174: ...OD 2 30 Jul 2018 H MAKI ...
Страница 175: ...OD 3 2 Oct 2018 H MAKI ...
Страница 176: ...OD 4 2 Oct 2018 H MAKI ...
Страница 178: ......
Страница 186: ......