Separate ground cable
A-9
A.6
Separate ground cable
A.6.1
To construct a ground cable
When dealing with electrical installations in a marine environment, all wiring must be
done with double insulated, tinned strands, high quality and if exposed also UV resistant
cables. This shall also apply to the separate ground cable mentioned in the previous
paragraphs.
The ground cable is constructed using an appropriate cable with a cross section area of at
least 6 mm
2
(AWG10) and terminated with insulated ring crimp terminals, see the
illustration below. The crimp terminals must be a marine approved type e.g. the DuraSeal
series from Raychem.
Figure A-6: Separate ground cable
Antenna
:
M12 Insulated Ring Terminal
(Raychem, DuraSeal Series)
Terminal
:
Appropriate size
Insulated Ring Terminal
(Raychem, DuraSeal Series)
Содержание FV-110GX
Страница 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Страница 16: ...xiv This page is intentionally left blank ...
Страница 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Страница 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Страница 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Страница 135: ...Alternative ground for steel hulls A 5 Figure A 3 Grounding at a dedicated RF ground alternative ...
Страница 164: ...Supported commands C 10 This page is intentionally left blank ...
Страница 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Страница 166: ...OEM declaration D 2 D 1 OEM declaration ...
Страница 173: ...OD 1 30 Jul 2018 H MAKI ...
Страница 174: ...OD 2 30 Jul 2018 H MAKI ...
Страница 175: ...OD 3 2 Oct 2018 H MAKI ...
Страница 176: ...OD 4 2 Oct 2018 H MAKI ...
Страница 178: ......
Страница 186: ......