Section 7: Model 9100: Specifications
7-25
Final Width = 215mm
7.18 Insulation/Continuity Specifications
7.18.1 Insulation Resistance Accuracy and Resolution (Super
I
)
Resistance Output
Accuracy
Absolute
Source Current
±
% of Output
Resolution
Limits
1Year — Tcal
±
5
°
C
[1]
100.0 k
Ω
to 299.9 k
Ω
0.1%
100
Ω
200
µ
A to 10mA
300.0 k
Ω
to 2.999 M
Ω
0.1%
1 k
Ω
90
µ
A to 4mA
3.000 M
Ω
to 29.99 M
Ω
0.3%
10 k
Ω
9
µ
A to 400
µ
A
30.00 M
Ω
to 299.9 M
Ω
0.5%
100 k
Ω
900nA to 40
µ
A
300.0 M
Ω
to 2.000 G
Ω
0.7%
1 M
Ω
90nA to 4
µ
A
7.18.2 Other Insulation Resistance Specifications
Maximum Measurement Voltage:
1350VDC: I x R < 1350V
Voltage Measurement:
Range:
0V to 1350V
Accuracy:
±
(0.6% of Output + 1V)
Current Measurement:
Range:
1
µ
A to 2.3mA
Accuracy:
±
1.5%