System Overview:
Quanta FEG Options
2-7
Quanta FEG Options
A range of hardware and software is available as options for the
system. Contact your FEI sales representative for more up-to-date
information on system options.
•
The
Support PC
connects your work space to the network and
can hold some other software utilities.
•
The
Manual User Interface (MUI)
provides direct manual control
of microscope parameters such as focus, magnification, contrast,
brightness, beam shift and Stigmator.
•
The
Joystick
brings another possibility to control the basic stage
movements.
•
The
Cooling Stage
enables to image and analyse specimens
(cooled between 0 and 10 °C) of very diverse nature at relative
humidity conditions up to 100% (typical chamber pressures
required are in the range 300 - 1000 Pa). Humidity experiments
could characterize the sample morphology and phase distribution.
The stage is cooled by water.
•
The
Waterless Cooling Stage
uses copper belt to detract heat
excess.
•
The
1000 °C Heating Stage
is used to view heated samples (up to
1000 °C) and record in-situ morphological changes.
•
The
1500 °C Heating Stage
enables to heat samples up to 1500 °C.
This option includes two 1500 °C and one 1000 °C heating stages.
•
The
Cooling / Heating Stage control kit
•
The
Feed-through Port Relocator
•
52-pin Electrical Feed-through
•
7-pin Electrical Feed-through
•
The
Compressor
115 V, 50/60 Hz with 4-liter Tank
•
The
Compressor
230 V, 50/60 Hz with 4-liter Tank
•
The
Thermo Neslab Water Cooler
50 Hz
•
The
Thermo Neslab Water Cooler
60 Hz
•
The
Acoustic Enclosure
for Pre-vacuum Pump
•
The
Specimen Holder Kit
•
The
Electrostatic Beam Blanker
•
The
Keithley picoamper meter
•
The
Picoamper meter Switch Box
•
The
Mains Matching
and Isolation Transformer
provides a
galvanic isolated AC-regulated power source with the 115 / 230 V,
50 / 60 Hz output.
•
The
CryoCleanerEC
+ spare vessel – anti-contamination device
•
The
Plasma Cleaner
– the sample / chamber plasma cleaning
device
•
The
Video Hard Copy Unit
•
5 paper rolls
for video hard copy unit
•
The
WetSTEM
detector enables in connection with the Cooling
Stage to observe wet samples in a STEM mode.
•
The
Gaseous Back-Scatter Electron Detector (GBSD)
allows
BSE imaging in ESEM™ mode, i.e. at a high chamber pressure (it
uses a gas amplification to compensate a signal loss). Other back-
scattered electron detectors (solid-state or scintillate-type BSE
detectors) typically work with a pressure up to 100 Pa, but tend to
get very noisy at this condition.
Содержание Quanta FEG 250
Страница 8: ...C vi...
Страница 28: ...System Operation Quanta FEG System States 3 10...
Страница 108: ...Alignments 1 Gun Alignment 6 6...
Страница 114: ...Alignments 154 Water Bottle Venting 6 12 154 Water Bottle Venting...
Страница 152: ...System Options Automatic Aperture System 9 4...
Страница 154: ...System Options Nav Cam 9 6 401 NAV CAM AUTOBRIGHTNESS...
Страница 177: ...System Options Cooling Stage Waterless Cooling Stage 9 29...