Chapter 9 Fieldbus I/O Interfaces
PAGE 9-7
Data Format in BANK : ON
(Extended Message Data)
(JDG: Judgment, OCR: Occurrence)
BANK
[OFF] 95 96 97 98 99
100
101
102 103 104 105 106 107
108
109
110
[ON ] 1 2 3 4 5
6 7
8 9 10 11 12 13
14
15
16
1ST TIME
JDG
OCR
2ND TIME
JDG
OCR
20H 31H 30H 2EH 30H 20H 20H 20H 20H 20H 32H 2EH 30H 48H 58H 20H
1
0
.
0
2
.
0
H
X
[OFF] 111
112
113
114
115
116
117 118
119
120
121
122
123
124
125 126 127 128 129 130 131 132
[ON ] 17
18
19
20 21 22 23
24
25 26 27 28 29 30 31
32 33 34 35 36 37 38
CYCLE TIME
PEAK TORQUE CURRNT
PEAK TORQUE ANGLE
RATE1 INC TORQUE
20H 20H 33H 2EH 31H 20H 31H 37H 2EH 31H
20H 20H 20H 32H 30H 20H 20H 20H 31H 2EH 32H 20H
3
.
1
1
7
.
1
2
0
1
.
2
[OFF] 133
134
135
136
137
138
139 140
141
142
143
144
145
146
147
148 149 150
[ON ] 39
40 41 42 43 44 45
46
47 48 49 50 51 52 53 54
55 56
RATE1 INC ANGLE
RATE2 INC TOEQUE
RATE2 INC ANGLE
20H 20H 20H 20H 33H 20H 20H 20H 38H 2EH 39H 20H 20H
20H 20H 31H 37H 20H
3
8
.
9
1
7
[OFF] 151
152
153
154
155
156
157 158
159
160
161
162
163
164
165 166
[ON ] 57
58 59 60 61 62 63
64
65 66 67 68
69
70 71
72
RATE3 INC TORQUE
RATE3 INC ANGLE
RUNDOWN REVO.
20H 20H 30H 2EH
30H 20H 20H 20H 20H
20H 30H 20H 20H
33H
2EH 35H
0
.
0
0
3
.
5
[OFF] 167
168
169
170
171
172
173 174
175
176
177
178
179
180
181 182
[ON ] 73
74 75 76 77 78 79
80
81 82 83 84 85
86
87
88
CALIBRATION VOLT
SIGN
ZERO VOLT
SNUG DETECTION TORQUE
JDG
32H 20H 31H 31H
20H 32H 36H 31H 20H
32H 2EH 33H 34H 20H 58H 20H
2
5
1
1
2
6
1
2
.
3
4
X
[OFF] 183
184
185
186
187
188
189 190
191
192
193
194 195 196 197 198 199 200
[ON ] 89
90 91 92 93 94 95
96
97 98 99 100 101 102 103 104 105 106 107
・・・・・・
200
00H 00H 00H 00H
00H 00H 00H 00H 00H
00H 00H 00H 00H 00H 00H 00H 00H 00H 00H
…
00H
…
JDG
"
X
"(58H)
:
REJECT
[PEAK TORQUE] JDG
"
H
"(48H)
:
Hight REJECT
"
L
"(4CH)
:
Low REJECT
"
A
"(41H)
:
Abnormal
"
S
"(53H)
:
STOP
"
R
"(52H)
:
RESET "
B
"(42H)
:
PROGRAM
"
D
"(44H)
:
START OFF(Start Trigger OFF before cycle complete)
※
"
A
","
B
","
D
","
R
","
S
" does not have occurrance.
[FINAL TORQUE],[
ANGLE
],[RATE],[TIME] JDG
"
H
"(48H)
:
Hight REJECT
"
L
"(4CH)
:
Low REJECT
REJECT Occurrence
"
X
"(58H)
:
Signifies the REJECT which
occured first.
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......