Chapter 6 Fastening Operation
PAGE 6-67
Angle
D-No. 200 Final Angle Low Limit
[deg]
D-No. 201 Final Angle High Limit
[deg]
Setting range: 0 ~ 9999.9
Sets the low and high limit values of the output judgment angle. When the fastening angle
exceeds the final angle high limit or falls below the final angle low limit, a REJECT judgment is made.
These are used to detect elongation or seizing of the fastener during fastening.
D-No. 203 1st Angle
[deg]
Setting range: 0 ~ 9999.9
This is the end point of 1st time from the start of fastening. Sets the torque value at which D-No. 401
[Freerun Speed] or D-No. 402 [1st Speed] is switched to D-No. 402 [2nd Speed]. Switching to D-No.
402 [2nd Speed] is also performed at the point at which D-No. 105 [1st Torque] or the 1st angle is
detected.
If the 1st angle is not to be used in the fastening control, input a value greater than D-No. 201 [Final
Angle High Limit].
D-No. 204 2nd Angle
[deg]
Setting range: 0 ~ 9999.9
When D-No. 109 [2nd Torque] or the 2nd angle is detected during operation at D-No. 402 [2nd Speed],
switching to D-No. 403 [3rd Speed] is performed.
If the 2nd angle is not to be used in the fastening control, input a value greater than D-No. 201 [Final
Angle High Limit].
・
If 2-step or 3-step fastening is used, set a Standard Angle value greater than D-No.
203 [1st Angle] to D-No. 204 [2nd Angle].
D-No. 205 Torque Inhibit Angle
[deg]
Setting range: 0 ~ 9999.9
Sets the torque inhibit rotation angle (if used). The tool will rotate this number of degrees ignoring the
torque (but will still monitor torque that it does not exceed the Torque Inhibit high limit)
* When the torque inhibit angle is set to “0,” the torque inhibit check will not be performed.
・
"Torque Inhibit " does not work with the following settings;
・
D-No. 004 [Output Judgment Item 2] :
“Torque Inhibit Judgment” “0”
・
D-No. 205 [Torque Inhibit Angle] :
“0”
D-No. 206 Differ Angle
[deg]
D-No. 207 Differential
– Angle
[deg]
Setting range: -999.9 ~ 999.9
The high and low limit values for the differential angle check are set. The differential angle
difference is judged from rate 2 and the final torque, regardless of the fastening method. To input a
negative value, move the cursor (flashing number) at the DATA Display
to the position of “P” and then
press the “
▲
” or “
▼
” button to make “-“ be indicated at the cursor position.
D-No.208 Option
[deg]
Setting range: 0 ~ 9999.9
*Not used
D-No.209 Correction Angle
[deg]
Setting range: -99.9 ~ 99.9
*
Default Setting: “0” [Only to be used if angle correction is necessary after checking with a master
tranducer]
D-No.211 Option
[deg]
Setting range: 0.1 ~ 10.0
*Not used
Caution
Caution
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......