Chapter 9 Fieldbus I/O Interfaces
PAGE 9-2
9-1 Common Fieldbus Specifications
9-1-1 Fieldbus I/O signal specifications
①
INPUT signal format
[PLC → HFC3000]
The input signal is a fixed layout.
Word
Byte
Singnal Name
Connection
Contents
No.
Bit#
No.
Bit#
IN
No.01
0
IN
No.01
0
Unused
NO
Always off.
1
1
Unused
NO
Always off.
2
2
Unused
NO
Always off.
3
3
Unused
NO
Always off.
4
4
BANK SELECT
NO
Fieldbus message bank reshuffling BIT.
In the case of CC-Link the top position of the message
data output can be changed (if data exceeds max
message size)
5
5
Unused
NO
Always off.
6
6
RESET
NO
Executes the following operation
by turning signal
“ON”.
・
Stop tightening process
・
Clears the PLC I / O fastening result output signals
(OFF)
・
Deletes any entered ID data
7
7
Unused
Always off.(
~
V1.300)
ID SELECT
ENABLE
NO
WORK number selection by input ID is enabled setting
this signal
“ON” (FirmwareV1.301
~
)
8
IN
No.02
0
Unused
NO
Always off.
9
1
Unused
NO
Always off.
10
2
Unused
NO
Always off.
11
3
Unused
NO
Always off.
12
4
Work Select Bit0
NO
Selects Parameter No.1~64 (Work Select 0~5)
13
5
Work Select Bit1
NO
14
6
Work Select Bit2
NO
15
7
Work Select Bit3
NO
IN
No.02
0
IN
No.03
0
STOP
NO or NC
Emergency Stop
1
1
RESET
NO
(See RESET signal above)
2
2
REVERSE
NO
Spindle will reverse (CCW) while
“ON”
3
3
START
NO
Starts fastening cycle
4
4
PROGRAM
NO
Bypasses the controller
5
5
SELF CHECK
Disable
NO
Disables self-check function
6
6
Unused
NO
Always off.
7
7
Unused
NO
Always off.
8
IN
No.04
0
Unused
NO
Always off.
9
1
Unused
NO
Always off.
10
2
Unused
NO
Always off.
11
3
Work Select Bit5
NO
Selects Parameter No.1~64 (Work Select 0~5)
12
4
BATCH OK RESET
NO
Resets Batch cycle count to 0.
13
5
Work Select Bit4
NO
Selects Parameter No.1~64 (Work Select 0~5)
14
6
Unused
NO
Always off.
15
7
Unused
NO
Always off.
* Work Select Bits 0 to 5 are enabled with the system parameter: SYS.034 [00xxx1].
(Continued on next page)
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......