Chapter 6 Fastening Operation
PAGE 6-46
System Parameters (Options)
SYS.030 Parameter Change Unlock Code
Standard setting: 000000
Allows the setting of a numerical password to restrict Parameter setting from the front display panel.
When a value other than the standard setting
(“000000”) is set, changing the controller to the
PROGRAM mode displays the password (numerical value) input screen.
By entering the value set in SYS.030 to the password input screen, the controller automatically will
change to the parameter setting screen/mode.
(This does NOT restrict changes from the HFC software
– only changes from the front display)
D-No.033 System Option 1
Standard setting: 000000
Option 1 functions setting
xxxxx1: Accept Relay
output (0:constant / 1:pulse)
・
Set to “1” for a QL-OK pulse type output signal of this output. “0” will be a constant output.
xxxx1x: Total Accept Relay Output (0:constant / 1:pulse)
・
Set to “1” for a TOTAL-OK pulse type output signal of this output. “0” will be a constant output.
xxx1xx: Accept Relay Output Timing (0:300msec / 1:800msec)
・
If the pulse method has been selected, select the pulse length here.
xx1xxx: Stop input (0: Open Stop / 1: Close Stop)
・
Set to “1” if the logic of the STOP input signal needs NOT to be ON to run (B type contact)
x1xxxx: Self check (0: at cycle start / 1: only the first cycle)
・
Set to "1" to perform the Zero/CAL check at the fastening start only in the first cycle.
(If the first cycle gets a judgement other than an ACCEPT, the check will be performed on the next
fastening cycle as well)
1xxxxx: Part ID input selection (0:Fieldbus / 1:RS232C-3)
・
For selecting whether the part ID data will be input from a fieldbus message or by the RS232C-3
port. (the part ID input is used for marrying part ID to the resultant fastening data)
D-No.034 System Option 2
Standard setting: 000000
Optional 2 functions Setting
xxxxx1: WORK/Parameter # change (0: Display panel / 1: PLC I/O Signal)
・
Set to “1” if the change of WORK/Parameter is to be performed from the PLC I/O (the change
cannot be performed from both the operation panel and the external I/O)
xxxx1x: Reversing switch (0: Slide / 1: Push Button)
·
0: P type, T type, Ltype, Dtype (Pistol, PTS, Zero Torque type)
·
1: A type, S type (Angle, Straight tool type)
xxx1xx: RS232C-1 output (0: PLC / 1: Ethernet)
·
0: RS232 outputs in ASCII PLC compatible format.
·
1: When using (optional) ETHERNET board (connected to RS232C-1)
xx1xxx: Reject (NG) result indication (0: enable / 1: disable)
・
Set to “1” to disable the Reject (NG) result display indication
x1xxxx: Fieldbus Function Disable (0:OFF / 1: ON)
・
Set to “1” to disable the Fieldbus when installed. (this will allow testing of the system without the
fieldbus interface being connected)
1xxxxx: WORK change priority (0: Fieldbus / 1: standard I/O)
・
When the WORK/Parameter change (first option 2 item) is set to PLC I/O, select which I/O type will
be used.
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......