Chapter 6 Fastening Operation
PAGE 6-47
D-No.035 System Option 3
Standard setting: 000000
Option 3 function setting
xxxxx1: Restrict cycle start after Total Accept (0: OFF ./ 1: ON).
・
Set to “1” to prohibit a restart after a TOTAL-OK
In order to restart the fastening operation, turn ON any of the following input signals.
RESET
STOP
PROGRAM
Note: Even if the PLC I/O input signal [BATCH OK RESET] is turned "ON", the fastening
operation will not re-start.
(Even if the spindle judgment is REJECT (NG), the next fastening start will not be
performed before Controller firmware version 1.300)
xxxx1x
:
Initial display of Fastening Results (0:D-No.00 / 1:D-No.37)
When the controller is powered up, set the initial display preference of the fastening result
mode.
・
0: D-No.00 Displays Peak Torque (only)
・
1: D-No.37 Displays Peak torque (upper part) / Final angle (lower part)
xxx1xx
:
Display Stop Status (0:During Stop Input / 1:At Startup after STOP)
Changes the STOP status (controller) display condition
• 0: Displays STOP while the PLC I / O input signal [STOP] is "ON"
• 1:Displays while the PLC I / O input signal [STOP] is "ON" and the rising edge of the PLC
I/O input signal [START (
REVERSE)] ("OFF" → "ON")
xx1xxx
:
CW / CCW Change Select (0:Ignore Tool CW/CCW switch / 1: Use Tool CW/CCW Switch)
When using a PLC START input signal, selects to ignore the tools CW/CCW switch or use
the CW/CCW switch for direction control
・
0: Ignores the tool CW/CCW switch position and starts the fastening (directed by the
programmed parameter direction)
・
1: Starts the fastening in the direction the tool CW/CCW switch is currently set in
x1xxxx
:
TB2-2_CF Warning signal output (0:Disable / 1:Enable)
Setup to use the PLC I/O output signal [CF WARNING] of I0 Terminal Block TB2-2.
・
0: Disable
– signal will not be output (do not connect)
・
1: Signal is output when the CF card remaining capacity is less than 200 MB on the
controller with the CF card option installed.
1xxxxx
:
Special Function 1(0:OFF / 1:ON)
Not Used
– Set to “0”
D-No.036 Gearhead Option
Standard setting: 0, Setting range: 0 ~ 2
0: Standard head 1: Regular tube nut (bottom socket) 2: Inverted tube nut (top socket)
D-No.037 Start (starting) Switch Level
Standard setting: 10, Setting range: 0 ~ 255
Please set 10.
D-No.038 High-speed Starting Switch Level
Standard setting: 40, Setting range: 0 ~ 255
Please set 40.
*Set to 10 for
‘push to start’ tool (D) type.
D-No.039 Reverse Switch Level
Standard setting: 10, Setting range: 0 ~ 255
Please set 10.
D-No.040~049 For Adjustment by the Manufacturer
Not used.
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......