Chapter 6 Fastening Operation
PAGE 6-58
Fastening Settings
D-No.000 Fastening Method
Standard setting: 0
Sets the Fastening Method.
0: Torque Method, 1: Angle Method
D-No. 001 Fastening Steps
Standard setting: 1
The number of steps used in fastening
1: 1-Step Fastening
・
Fastening is performed using D-No. 103 [Standard Torque] or D-No. 202 [Standard Angle] as a
target stopping point (with no stops in between)
2: 2-Step Fastening
・
After fastening is started, the fastening is stopped momentarily at D-No. 105 [1st Torque] or D-No.
203 [1st Angle] before continuing to the target torque or angle. (the stop time between steps
differs by system and may be unnoticeable viewing the spindle rotation).
3: 3-Step Fastening
・
After fastening is started, fastening is stopped momentarily twice, at D-No. 105 [1st Torque] or
D-No. 203 [1st Angle] and at D-No. 109 [2nd Torque] or D-No. 204 [2nd Angle]. After the second
momentary stop, fastening to the set target value is performed. (the stop time between steps
differs by system and may be unnoticeable viewing the spindle rotation).
D-No. 002 Fastening Option
Standard setting: 010000
The option used in fastening is set.
*****1: Reverse Before Fastening (can only be used in the single system)
・
Before the start of the fastening operation, reverse rotation at D-No. 405 [Reverse 1 Speed] is
executed for D-No. 505 [Reverse Revolutions before Fastening].
****1*: Fastening Direction CCW
・
This is a special fastening option for performing a screw loosening operation or for fastening
left-hand screws, etc. Using this setting, normal rotation is performed in the CCW direction
(counterclockwise direction) and reverse rotation is performed in the CW direction (clockwise
direction).
***1**: Torque Hold Between Steps [
NOT USED FOR HFC3000
]
・
In 2-step fastening, 1/4 of the Standard Torque setting is maintained upon reaching 1st step (1st
torque, 1st angle) stopping until the subsequent fastening operation is restarted.
・
In 3-step fastening, 1/4 of the torque setting is maintained during the 1st step (1st torque, 1st
angle) and the 2nd step (2nd torque, 2nd angle) until the subsequent fastening operation is
restarted.
**1***: Disable Stored Curve Data Save
・
Disables curve storage (in controller) after the end of fastening (a Reject (NG) curve would still be
stored).
*1****: Disable Angle Count Below Snug Torque
・
Angle measurement is suspended while torque lower than Snug Torque is detected. (Final Angle
will only be reported when torque is at or above Snug Torque)
* When this is
“0”, the angle measurement is continued regardless of the value of the torque after
Snug Torque is first detected.
1*****
:
Option [Not Used]
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......