Chapter 4 Installation and Wiring
PAGE 4-8
4-5-1 Controller I/O Signals
System parameter: SYS.033[xxx1xx] 0: 300ms/1: 800ms pulse length
Pin No.
Signal
IN/OUT
Description of Function/Usage
TB3-1
IN COMMON
IN
Common input signal (bipolar)
TB3-2,11
+24V
Service power
supply
0.5Amax
+24V output When using this power supply, keep wiring away from
electrical noise exposure.
TB3-3,12
GND
GND
TB1-1
STOP
IN-1(A:NO/
B:NC)
The fastening process
is stopped when this signal is set to “OFF.”
Selection between A contact and B contact type is possible.
System parameter: SYS.033[xx1xxx] 0: A contact/1: B contact
TB1-2
RESET
IN-2(NO)
The fastening process is stopped and the fastening judgment of the
controller is cleared
when set “ON.” (ID data is cleared as well.)
TB1-3
REVERSE
IN-3(NO)
The tool rotates in reverse
direction while “ON” and at the speed in
accordance with the selected WORK No. (Parameter)
TB1-4
START
IN-4(NO)
When
“ON”, the fastening process is started in accordance with the
selected WORK No. (“Deadman” specification).
TB1-5
PROGRAM(BYPASS)
IN-5(NO)
The controller is put in the BYPASS (PROGRAM) mode when
“ON”.
TB1-6
SELF CHECK
DISABLE
IN-6(NO)
When set
“ON”, the self-check of the torque transducer (Zero Level /
Cal level voltage check) will not be performed (normally before the
start of the fastening operation - the start of tool rotation can be
shortened by approx. 60msec).
TB1-7
WORK SELECT BIT 0
IN-7(NO)
The WORK SELECT BIT 0
~
4 select signals enable selection
among parameter Nos. 1
~
32 by a (Binary) combination of the 5 pin
Nos. (See Work Select table further below)
TB1-8
WORK SELECT BIT 1
IN-8(NO)
TB1-9
WORK SELECT BIT 2
IN-9(NO)
TB1-10
WORK SELECT BIT 3
IN-10(NO)
TB1-11
WORK SELECT BIT 4
IN-11(NO)
TB1-12
BANK SELECT
IN-12(NO) Bank select input signal (changes output signal definition)
TB3-4
OUT COMMON
OUT
Common output signal (bipolar)
TB3-5
BATCH OK RESET
IN-13(NO) Cycle counter (ACCEPT count) reset signal
TB3-6
IN-14 NO
Not USED
TB3-7
Bank Select Output
OUT-6(NO) Output definition depends on status of Bank Select Input (TB1-12)
(See next page for output definition)
TB3-8
Bank Select Output
OUT-7(NO)
TB3-9
Work Select Bit 5
IN-15 NO
The Work Select Bit 5 enables selection of parameters 33-64 in
combination with Work Select Bits 0-4 (Firmware Ver. 1.301 or later)
TB3-10
ID Work Select Enable
IN-16 NO
Thw Work number selection by ID data input is enabled when ON.
(Firmware Ver. 1.301 or later)
TB2-1
Bank Select Output
OUT-1(NO)
Output definition depends on status of Bank Select Input (TB1-12)
(See next page for output definition)
TB2-2
Bank Select Output
OUT-2(NO)
TB2-3
Bank Select Output
OUT-3(NO)
TB2-4
Bank Select Output
OUT-4(NO)
TB2-5
Bank Select Output
OUT-5(NO)
TB2-6
Bank Select Output
OUT-12(NO)
TB2-7
MANREV (RY1-1)
OUT-8(NO)
Turns ON when manually starting the reversed operation.
Turns OFF when the next fastening starts or turns OFF at RESET,
PROGRAM. (Relay contact-1)
TB2-8
BUZZER (RY2-1)
OUT-9(NO)
Performs a duplication of the controller buzzer output of the REJECT
signal and Batch OK to external devices.
(Relay contact-2)
TB2-9
BATCH OK (RY3-1)
[TOTAL OK]
OUT-10(NO)
Output when the fastening results are OK for the programmed number
of cycles when using batch counting function (relay contact-3).
Selection between pulse or constant output is possible.
System parameter: SYS.033[xxxx1x] 0: constant 1: pulse
TB2-10
RY-COM(RY1,2,3-2)
OUT
Relay contact-1, 2, 3 common
TB2-11
TB2-12
QL OK (RY4-1)
[OK] (RY4-2)
OUT-11(NO)
OK output for QL Accept signal (relay contact) (Relay contact-4)
Selection between pulse and constant output is possible.
System parameter: SYS.033[xxxxx1] 0: constant 1: pulse
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......